User`s manual
Schilling Marking Systems GmbH
In Grubenäcker 1 DE-78532 Tuttlingen
+49 (0)7461 9472-0 +49 (0)7461 9472-20
info@schilling-marking.de
www.schilling-marking.de
  MK3 - User’s Manual  52 
  Detailed operating instructions 
5.18.3 Marking quality 
Impact marking quality includes all settings affecting the impact marking results, which are as follows: 
•  Travel speed of the marking needle 
•  Needle frequency (= density of impact marking points) 
•  Pulse duration of pressurisation (= impact marking depth) 
The travel speed is the speed at which the impact marking needle is moved during marking. Due to 
the fact that the marking needle is operated at a set needle frequency, the travel speed, together with 
the needle frequency, is important for the density of marking points and therefore of great importance 
to the image of the marking. 
Pulse duration is a measure of the energy by which the marking needle impacts the workpiece and 
therefore a measure of the impact marking depth of a specific material. 
In order to change the impact marking quality, select ”Marking quality” form the ”Options” menu. This 
will open the ”Marking quality” prompts window which will be displayed as follows: 
Fig. 25: Marking quality prompts - Travel speed, needle frequency and pulse duration 
You may now enter the settings for the marking quality as follows: 
1.) In steps by setting a suitable value 
or 
2.) infinitely variable by setting the slide ruler. 