  MK3 - User’s Manual  62 
 Maintenance 
6.4  MEANING OF THE LED 
TYPE MEANING  NOTES 
+35  MOTOR ELECTROVALVE POWER  +35 Volt 
+24  I/O AUXILIARY CIRCUIT POWER  +24 Volt 
+12  ELECTROVALVE SERVICE POWER  +12 Volt 
+5P  MOTOR LOGIC POWER  +5 Volt 
+5L  CONTROLLER POWER  +5 Volt 
EV  ELECTROVALVE ON  on for EV enabled 
ST  INPUT OF MARKING START  on for START enabled 
SP  INPUT OF MARKING STOP  on for STOP enabled 
RD  CONTROLLER OK  on for Controller OK 
FM  MARKING END  off during the marking 
PU  STYLUS COMMAND  on for stylus enabled 
MP  PRESSURE MIN.  on for min. pressure switch closed 
IM  MOTOR RESOLUTION  1 - ½ step 
EN  MOTOR ENABLE  on for motors free 
CX  CLOCK MOTOR X  on at each step of the motor movement X 
CY  CLOCK MOTOR Y  on at each step of the motor movement Y 
CZ  CLOCK MOTOR C OR Z  on at each step of the motor movement C or Z 
! ATTENTION ! If in the SM-Program C- or Z-axis is akivated, the Y-axis is deactivated 
DX  DIRECTION MOTOR X  off for motor to direction X zero mechanic 
DY  DIRECTION MOTOR Y  on for motor to direction Y zero mechanic 
DZ  DIRECTION MOTOR C OR Z  on for motor to direction C or Z zero mechanic 
FX  END TRAVEL AXIS X  on for end travel X on zero mechanic 
FY  END TRAVEL AXIS Y  on for end travel Y on zero mechanic 
FZ  END TRAVEL AXIS C OR Z  on for end travel C or Z on zero mechanic 