Tribunus VII+ 200A ESC - Manual

How to DIY your own Telemetry/setup cable for the Tribunus ESCs – Vbar NEO: http://www.scorpionsystem.com/blog/?p=6663
Cables are also available as a VBar Control Accessoire at Mikados onlineshop (no.: 05088 350mm and no.: 05089 500mm)
After connecting the telemetry cable from Tribunus ESC PC port to your telemetry port of the VBar NEO do the following steps:
-Connect your VBar Control to VBar Control manager and download the “Scorpion ESC Support App
-After that make sure the app is enabled with a “(X)” in your application enable” menu of your radio.
-Install the latest rmware on your ESC (V52 or higher).
-On V52 or higher VBar is the standard communication protocol of your Tribunus ESC, communication to VBar Control is enabled
Page 11
TRIBUNUS ESC AND MIKADO VBAR CONTROL/ VBAR NEO INTEGRATION
13 Tribunus ESC and VBar Control
13.1 Tribunus ESC telemetry/ setup cable for VBar
13.2 Tribunus ESC and VBar Control telemetry preparation before setup
Once the previous steps are done there will be a Scorpion
icon on VBar Control display, then setup of Tribunus ESC
can start using VBar Control radio.
Attention:
The cables from the ESC master and slave both have BEC output when it is enable.
DO NOT plug in the Vbar “SENSOR” port, this will kill the VBar and void the warranty.
The throttle cable only connect to Vbar ESC port, the rpm wire plugs into the RPM port.