C1448, C1848, C2148W Air and Water Cooled User Manual Introduction The design of this modular cuber is the result of years of experience and testing. Standard features include front accessible indicator lights and on-off switches that provide the user with fast access to critical information and easy operational control. When desired, optional controls can add features like ultrasonic bin ice level sensing, seven day programmable bin ice level setting, remote lock out and more.
C1448, C1848, C2148W Air and Water Cooled User Manual Installation: Product Specifications Location Limitations: The product is designed to be Environmental Limitations installed indoors, in a controlled environment. Air cooled models discharge very warm air into the Minimum room out the back. Space must be allowed at the Air temperature 50oF. left side and back for air intake and discharge. Water cooled models discharge warm water into Water 40oF. the building’s drain.
C1448, C1848, C2148W Air and Water Cooled User Manual Product Information The product is a modular cuber. That type of Options: machine is designed to be placed on an ice storage bin or an ice dispenser. Many installations only There are several field-installed options that can be require the matching bin, but some also require an installed at initial start up or later. They include: adapter to be placed between the bin and the cuber or between the dispenser and the cuber.
C1448, C1848, C2148W Air and Water Cooled User Manual Product Description & Electrical Requirements Dimensions w” x d” x h” Model Electrical Condenser Minimum Circuit Ampacity Maximum Fuse Size* 48 x 24 x 29 C1448SA-32 208-230/60/1 Air 17.7 30 same C1448SW-32 208-230/60/1 Water 16.0 30 same C1448SA-3 208-230/60/3 Air 13.6 15 same C1448SW-3 208-230/60/3 Water 11.9 15 same C1848SA-32 208-230/60/1 Air 25.5 30 same C1848SW-32 208-230/60/1 Water 23.
C1448, C1848, C2148W Air and Water Cooled User Manual Cabinet Layout, Air Cooled November 2006 Page 5
C1448, C1848, C2148W Air and Water Cooled User Manual Cabinet Layout, Water Cooled November 2006 Page 6
C1448, C1848, C2148W Air and Water Cooled User Manual Water The quality of the water supplied to the ice machine will have an impact on the time between cleanings and ultimately on the life of the product. There are two ways water can contain impurities: in suspension or in solution. Suspended solids can be filtered out. In solution or dissolved solids cannot be filtered, they must be diluted or treated. Water filters are recommended to remove suspended solids.
C1448, C1848, C2148W Air and Water Cooled User Manual Panel Removal 1 2 3 Locate and loosen the two screws at the front edge of the top panel. Switch Bezel All models ship with the On and Off switches front Pull the front panel out at the top until it clears accessible. if desired, the On and Off switches can the top panel. be covered up to prevent unauthorized use by changing the bezel in the front panel's trim strip. A Lift the front panel up and off the machine.
C1448, C1848, C2148W Air and Water Cooled User Manual Uncrate and Set Up Begin with unpacking the ice storage bin. Remove the carton, and using part of the carton as a cushion, tip the bin on its back to remove the skid and attach the legs or casters. Bin Recycling Many times an ice machine head will be replaced, while the existing ice storage bin will be reused.
C1448, C1848, C2148W Air and Water Cooled User Manual Plumbing Requirements All models require connection to cold, potable water. A hand actuated valve within site of the machine is required. Air cooled models have a single 3/8” FPT inlet water connection, a 3/8” FPT to 3/8” male flare adapter is supplied with the machine and can be used if desired. Water Filters If connecting to water filtration, filter only the water to the reservoir, not to the condenser.
C1448, C1848, C2148W Air and Water Cooled User Manual Drains 3 Route the drain tubing to building drain. Follow All models require drain tubing to be attached to local codes for air gap. them. Air cooled models have a single ¾” FPT drain fitting in the back of the cabinet. Water cooled models have the same fitting plus an additional ½” Use rigid drain tubes and then route them FPT drain fitting in the back of the cabinet.
C1448, C1848, C2148W Air and Water Cooled User Manual Electrical The machine is not supplied with a power cord, one must either be field installed or the machine hard-wired. The dataplate on the back of the cabinet details the power requirements, including voltage, phase, minimum circuit ampacity and maximum fuse size. HACR type circuit breakers may be used in place of fuses. Extension cords are not permitted. Use of a licensed electrician is recommended.
C1448, C1848, C2148W Air and Water Cooled User Manual Final Check List After connections, 1 Wash out the bin. If desired, the interior of the bin could be sanitized. 2 Locate the ice scoop (if supplied) and have it available for use when needed.
C1448, C1848, C2148W Air and Water Cooled User Manual Initial Start Up 1 Remove front panel. Check machine for any packing or wires rubbing moving parts. Note location of control board in upper left corner of the machine’s front. 2 Remove tape securing each curtain to its evaporator. 3 Switch on the electrical power to the machine. Observe that some of the control’s indicator lights glow and its display shows O. 4 Open the water supply valve. 5 Push and release the ON button.
C1448, C1848, C2148W Air and Water Cooled User Manual Adjustments Bridge Thickness - For Service Tech Only 1 Push and hold Off till the machine stops. 2 Remove evaporator cover. 3 Remove curtain. 4 Use a box wrench and rotate the bridge thickness adjustment screw in 1/8 turn increments CW to increase bridge thickness. Rotate CCW to decrease bridge thickness. Caution: Do not make the bridge too thin or the machine will not harvest properly. Bridge thickness adjustments are not covered by warranty.
C1448, C1848, C2148W Air and Water Cooled User Manual Water flush setting The water flush is factory set to the automatic position, suitable for most water conditions. The setting can be changed to one of 5 manual settings or left on automatic.
C1448, C1848, C2148W Air and Water Cooled User Manual Use and Operation Once started, the ice machine will automatically make ice until the bin or dispenser is full of ice. When ice level drops, the ice machine will resume making ice. Caution: Do not place anything on top of the ice machine, including the ice scoop. Debris and moisture from objects on top of the machine can work their way into the cabinet and cause serious damage. Damage caused by foreign material is not covered by warranty.
C1448, C1848, C2148W Air and Water Cooled User Manual Switches The panel in the front of the machine can be flipped Adjustable ice level control up to access two switches – on and off. When this option is present there is an adjustment post and an additional indicator light to the right of Status De-Scale Off the four indicator lights mentioned above. The ultrasonic ice level control allows the use to control the point that the ice machine will stop making ice before the bin or dispenser is full.
C1448, C1848, C2148W Air and Water Cooled User Manual Options and Other Information SmartBoard Ice When this option is present there is an additional display panel in the area below the main control board. It is not visible when the front panel is on. The SmartBoard’s features include: The cuber drops ice in large sections. That ice will break up into random parts as it falls into the bin, but some large sections may remain on top of the ice in the bin.
C1448, C1848, C2148W Air and Water Cooled User Manual Cleaning, Sanitation and Maintenance This ice system requires three types of maintenance: • Remove the build up of mineral scale from the ice machine’s water system and sensors. • Sanitize the ice machine’s water system and the ice storage bin or dispenser. • Clean or replace the air filter and clean the air cooled condenser (air cooled models only). It is the User’s responsibility to keep the ice machine and ice storage bin in a sanitary condition.
C1448, C1848, C2148W Air and Water Cooled User Manual 13 Remove water distributors from ice machine. Inspect each distributor for restricted orifice holes. Be sure all holes are full open. 17 Thoroughly wash all surfaces of the ice thickness sensor, water level sensor, curtain and water distributor with the sanitizer solution.
C1448, C1848, C2148W Air and Water Cooled User Manual Air cooled condenser filter 1 Pull air filters from their louvered mounts. Maintenance 2 Wash the dust and grease off the filter. Air cooled condenser 3 Return them to their original positions. If the machine has been operated without a filter the air cooled condenser fins will need to be cleaned. Do not operate the machine without the filter in place except during cleaning. Push and release the Off button. Wait until the machine stops.
C1448, C1848, C2148W Air and Water Cooled User Manual What to do before calling for service Reasons the machine might shut itself off: • • • • • Lack of water. Freeze cycle takes too long. Harvest cycle takes too long. High discharge temperature. Controller self test failure. Check the following: 1. Has the water supply to the ice machine or building been shut off? If yes, the ice machine will automatically restart within 25 minutes after water begins to flow to it. 2.