Installation and User’s Manual for Modular Cuber Prodigy Plus D Series Models C0322, C0522, C0722, C0330, C0530, C0630, C0830 and C1030
C0322 through C1030 D Series Air and Water Cooled User Manual Introduction The design of this modular cuber is the result of years of experience and testing. Standard features include front accessible indicator lights and on-off switches that provide the user with fast access to critical information and easy operational control. Keep this manual for future reference.
C0322 through C1030 D Series Air and Water Cooled User Manual Installation: Product Specifications Location Limitations: Environmental Limitations The product is designed to be installed indoors, in a controlled environment. Air cooled models discharge very warm air into the room out the back. Space must be allowed at the sides and back for air discharge. Water cooled models discharge warm water into the building’s drain. Space needs to be provided on both sides and above for service access.
C0322 through C1030 D Series Air and Water Cooled User Manual Model Number Description Example: Hotel Dispensers • • • • • The HD22 and HD30 are compatible with this ice machine, no adapters are needed. Some typical combinations include: • • • C0322SA-1D C= cuber 03= nominal ice capacity in 100s of pounds 22= nominal width of cabinet S= Cube size. S=small or half dice cube. M=medium or full dice cube A=Condenser type. A=air cooled.
C0322 through C1030 D Series Air and Water Cooled User Manual Product Description & Electrical Requirements Dimensions w" x d" x h" Model 22.6** x 24 x 23 30.6** x 24 x 23 22.6** x 24 x 29 30.6** x 24 x 29 Series Electrical volts/Hz/ phase Condenser Minimum Circuit Ampacity Maximum Fuse Size* C0322SA-1 D 115/60/1 Air 12.7 15 C0322SW-1 D 115/60/1 Water 11.9 15 C0322MA-32 D 208-230/60/1 Air 6.1 15 C0522SA-1 D 115/60/1 Air 13.8 15 C0522SW-1 D 115/60/1 Water 12.
38.8 15.28 December 2014 Page 5 3/8" FPT WATER INLET 4.1 1.62 4.1 1.60 3.6 1.43 7.7 3.03 27.4 10.78 .88" DIA ELECTRICAL ACCESS 5.1 2.02 3/4" FPT DRAIN 3/8" FPT WATER INLET AIR COOLED BACK VIEW 9.5 3.73 4.3 1.68 WATER COOLED BACK VIEW 1/2" FPT CONDENSER DRAIN 3/8" FPT CONDENSER WATER INLET 19 7.47 3.6 1.43 3/4" FPT DRAIN 7.7 3.04 27.4 10.79 37 14.56 .88" DIA ELECTRICAL ACCESS 37 14.55 50.1 19.71 48.3 19.00 REMOTE CONDENSER LIQUID LINE 3/8 MALE CPLG. 4.3 1.
December 2014 Page 6 AIR COOLED BACK VIEW 3/8" FPT WATER INLET .88" DIA. ELECTRICAL ACCESS 4.3 1.71 20.2 7.94 4.2 1.64 7.8 3.08 42.7 16.83 3/4" FPT DRAIN 63.1 24.83 LEFT SIDE VIEW 61 24.00 63.7 25.09 ULTRASONIC BIN LEVEL SENSOR (OPTIONAL) 73.7 29.00 24.00 REF. 5.75 17.8 7.00 FRONT VIEW 55.9 22.00 57.7 22.70 PLAN VIEW 22.00 REF. 26 10.25 8.3 3.25 LOUVERS AND REMOVABLE FILTERS (2) AC UNITS ONLY 5.1 2.00 48.4 19.05 5.1 2.
WATER COOLED BACK VIEW 1/2" FPT CONDENSER DRAIN December 2014 Page 7 4.4 1.73 3/4" FPT DRAIN 7.8 3.07 27.3 10.76 3/8" FPT WATER INLET .88" DIA ELECTRICAL ACCESS 5.3 2.07 3.8 1.48 AIR COOLED BACK VIEW 3/8" FPT WATER INLET 28.2 11.10 6.7 2.62 37.8 14.87 36.9 14.53 3.7 1.48 46 18.11 3/4" FPT DRAIN 7.8 3.06 27.5 10.81 37 14.59 .88" DIA ELECTRICAL ACCESS 4.3 1.70 47.6 18.76 REMOTE CONDENSER LIQUID LINE 3/8 MALE CPLG. 46 18.11 6.7 2.62 3.8 1.48 37 14.57 LEFT SIDE VIEW 61 24.
43.5 17.14 12.4 4.87 WATER COOLED BACK VIEW 1/2" FPT CONDENSER DRAIN 3/8" FPT CONDENSER WATER INLET December 2014 Page 8 15.4 6.07 AIR COOLED BACK VIEW 3.7 1.48 11.7 4.62 3/8" FPT WATER INLET 5.4 2.12 52.3 20.59 4.4 1.73 3/4" FPT DRAIN 7.8 3.07 34.2 13.47 3/8" FPT WATER INLET .88" DIA ELECTRICAL ACCESS 61.1 24.06 3.7 1.48 3/4" FPT DRAIN 7.8 3.06 34.1 13.44 52.2 20.56 .88" DIA ELECTRICAL ACCESS 4.3 1.70 62.9 24.76 REMOTE CONDENSER LIQUID LINE 3/8 MALE CPLG.
C0322 through C1030 D Series Air and Water Cooled User Manual Water The quality of the water supplied to the ice machine will have an impact on the time between cleanings and ultimately on the life of the product. Water can contain impurities either in suspension or in solution. Suspended solids can be filtered out. In solution or dissolved solids cannot be filtered, they must be diluted or treated. Water filters are recommended to remove suspended solids.
C0322 through C1030 D Series Air and Water Cooled User Manual Panel Removal 1. Locate and loosen the two screws at the bottom of the front panel. 6 2. Pull the front panel out at the bottom. 3. Lower the front panel down and off the machine. 4 Dataplate Location 4. Remove two screws at the front of the top panel. Lift up the front of the top panel, push the top panel back an inch, then lift to remove. 5. Locate and loosen the screws holding each side panel to the base.
C0322 through C1030 D Series Air and Water Cooled User Manual Plumbing Requirements All models require connection to cold, potable water. A hand actuated valve within site of the machine is required. Air cooled models have a single 3/8” FPT inlet water connection; a 3/8” FPT to 3/8” male flare adapter is available from the local Scotsman distributor or from a hardware store.
C0322 through C1030 D Series Air and Water Cooled User Manual Electrical The machine is not supplied with a power cord as the machine is designed to be permanently connected. The dataplate on the back of the cabinet details the power requirements, including voltage, phase, minimum circuit ampacity and maximum fuse size. HACR type circuit breakers may be used in place of fuses. Extension cords are not permitted. Use of a licensed electrician is recommended.
C0322 through C1030 D Series Air and Water Cooled User Manual Final Check List After connections, 1. Wash out the bin. If desired, the interior of the bin could be sanitized. 2. Locate the ice scoop (if supplied) and have it available for use when needed. Final Check List: 9. Have the drain connections been checked for leaks? 10. Has the bin interior been wiped clean or sanitized? 11. Have any water filter cartridges been replaced? 12. Have all required kits and adapters been properly installed? 1.
C0322 through C1030 D Series Air and Water Cooled User Manual Initial Start Up 1. Remove front panel and evaporator cover. Check machine for any packing or wires rubbing moving parts. 2. Switch on the electrical power to the machine. Observe that some of the control’s indicator lights glow and its display shows O. 3. Open the water supply valve. 4. Locate lower light and switch panel. Push and release the ON button on that panel. The code display will begin to blink F.
C0322 through C1030 D Series Air and Water Cooled User Manual Adjustments Ice Bridge Thickness Measurement Bridge Thickness - For the Service Tech Only Note: Indentations may be deeper on C0322 and C0330 1/8-3/16” bridge 1. Push and hold Off till the machine stops. 2. Remove evaporator cover. 3. Remove curtain. 4. Use a hex wrench and rotate the bridge thickness adjustment screw in 1/8 turn increments CW to increase bridge thickness. Rotate CCW to decrease bridge thickness.
C0322 through C1030 D Series Air and Water Cooled User Manual Use and Operation Once started, the ice machine will automatically make ice until the bin or dispenser is full of ice. When ice level drops, the ice machine will resume making ice. Caution: Do not place anything on top of the ice machine, including the ice scoop. Debris and moisture from objects on top of the machine can work their way into the cabinet and cause serious damage. Damage caused by foreign material is not covered by warranty.
C0322 through C1030 D Series Air and Water Cooled User Manual Control Switches The On and Off switch buttons are front accessible. De-scale Status Power Water Off On To switch the machine OFF, push and release the Off button. The machine will shut off at the end of the next cycle. To shut the machine off immediately, push and hold the Off button for 3 seconds. To switch the machine ON, push and release the On button. The machine will go through a start up process and then resume ice making.
C0322 through C1030 D Series Air and Water Cooled User Manual Cleaning, Sanitation and Maintenance This ice system requires three types of maintenance: • • • Remove the build up of mineral scale from the ice machine’s water system and sensors. Sanitize the ice machine’s water system and the ice storage bin or dispenser. Clean or replace the air filter and clean the air cooled condenser (air cooled models only).
C0322 through C1030 D Series Air and Water Cooled User Manual 11. Wash the sensor and the adjustment screw with ice machine scale remover solution, rinse with clean water. Also wash the water distributor and curtain with the ice machine cleaner solution. Squeeze Tabs Together, Slide Out Until it Stops, Then Lift to Remove positions. Be sure water level sensor and ice thickness sensor are completely dry. 18. Push and release the Clean button. The yellow Clean light will blink and the display will show C.
C0322 through C1030 D Series Air and Water Cooled User Manual Air cooled condenser filter Clean air filters when they become visibly dirty. They will need cleaning more often than the other items. Air Filter 1. Pull air filter(s) from the front panel. Water filters 2. Wash the dust and grease off the filter. If the machine has been connected to water filters, check the cartridges for the date they were replaced or for the pressure on the gauge.
C0322 through C1030 D Series Air and Water Cooled User Manual What to do before calling for service Reasons the machine might shut itself off: • • • • • Lack of water. Freeze cycle takes too long. Harvest cycle takes too long. High discharge temperature. Controller self test failure. Check the following: 1. Has the water supply to the ice machine or building been shut off? If yes, the ice machine will automatically restart within 25 minutes after water begins to flow to it. Curtain 2.
SCOTSMAN ICE SYSTEMS 775 Corporate Woods Parkway Vernon Hills, IL 60061 www.scotsman-ice.