Installation and User’s Manual for Remote Condenser Modular Cuber Prodigy Plus D Series Models C1448R, C1848R, C2148R
C1448, C1848, C2148 D Series Remote Condenser Models - User Manual Introduction The design of this modular remote cuber is the result of years of experience with remote ice machine refrigeration systems. Standard features of this product include front accessible on-off switches, always-visible indicator lights, mechanical assist ice harvest for extra efficiency, automatically adjusting water purge and a control system that optimizes system operation.
C1448, C1848, C2148 D Series Remote Condenser Models - User Manual Installation: Product Specifications Location Limitations Warranty Information This ice system is made up of three parts, the ice making machine, or head; the remote condenser; and the interconnecting tubing. The ice making machine must be installed indoors, in a controlled environment. Space must be provided near the machine for service access.
C1448, C1848, C2148 D Series Remote Condenser Models - User Manual Model Number Description Example Other bins and applications: • C1448SR-32D Note the drop zone and optional ultrasonic sensor locations in the illustrations. • C=cuber Scotsman ice systems are designed and manufactured with the highest regard for safety and performance. They meet or exceed the standards of UL and NSF.
C1448, C1848, C2148 D Series Remote Condenser Models - User Manual Product Description and Electrical Requirements Dimensions w” x d” x h” Model Electrical Use condenser 48 x 24 x 29 same same same same same same same C1448SR-32 C1448SR-3 C1448MR-32 C1848SR-32 C1848MR-32 C1848SR-3 C2148SR-3 C2148MR-3 208-230/60/1 208-230/60/3 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/3 208-230/60/3 208-230/60/3 ERC311-32 ERC311-32 ERC311-32 ERC611-32 ERC611-32 ERC611-32 ERC611-32 ERC611-32 Minimum Circuit Am
C1448, C1848, C2148 D Series Remote Condenser Models - User Manual Condenser and Machine Layouts .88 DIA. ELECTRICAL INLET 29.50 in 74.9 cm DISCHARGE LINE 1/2" MALE CPLG. 2.75 LIQUID LINE 3/8" MALE CPLG. 38.47 in 97.7 cm Cond. Fins 32.32 in 82.1 cm 35.72 in 90.7 cm AIR FLOW 28.07 in 71.2 cm 24.71 in 62.7 cm 23.54 in 59.7 cm .562 DIA. MOUNTING HOLES (4) 2.84 in 7.2 cm 11.50 in 29.2 cm 14.56 in 36.9 cm 29.15 in 74.0 cm REMOTE CONDENSER LIQUID LINE 3/8 MALE CPLG. 61.4 24.18 30 11.83 29.
C1448, C1848, C2148 D Series Remote Condenser Models - User Manual Water The quality of the water supplied to the ice machine will have an impact on the time between cleanings and ultimately on the life of the product. There are two ways water can contain impurities: in suspension or in solution. Suspended solids can be filtered out. In solution or dissolved solids cannot be filtered, they must be diluted or treated. Scotsman filters: A triple head filter is recommended.
C1448, C1848, C2148 D Series Remote Condenser Models - User Manual Panel Removal 1. Locate and loosen the two screws at the bottom edge of the front panel. 5 2. Pull the front panel out at the bottom until it clears the base. 3. Lower the front panel down and off the machine. 6 4. Remove two screws from the front edge of the top panel. 5. Lift up the front of the top panel, push it back an inch, then lift to remove. 6. Locate and loosen the screw holding each side panel to the base. 1 7.
C1448, C1848, C2148 D Series Remote Condenser Models - User Manual Remote Condenser Location Use the following for planning the placement of the condenser relative to the ice machine Location Limits - condenser location must not exceed ANY of the following limits: • Maximum rise from the ice machine to the condenser is 35 physical feet Configurations that do NOT meet these requirements must receive prior written authorization from Scotsman. Do NOT: • Route a line set that rises, then falls, then rises.
C1448, C1848, C2148 D Series Remote Condenser Models - User Manual For The Installer: Remote Condenser Locate the condenser as near as possible to the interior location of the ice machine. Meet all applicable building codes. Spacing. Some unique installations have a ceiling over the top of the condenser fan. It must be at least 24 inches from the fan guard. Space at the coil sides must also be at least 24 inches from a wall.
C1448, C1848, C2148 D Series Remote Condenser Models - User Manual Precharged Line Routing Do not connect the precharged tubing until all routing and forming of the tubing is complete. See the Coupling Instructions for final connections. 1. Each set of pre-charged tubing lines contains a 3/8” diameter liquid line, and a 1/2” diameter discharge line. Both ends of each line have quick connect couplings, the end without access valves goes to the ice maker.
C1448, C1848, C2148 D Series Remote Condenser Models - User Manual Coupling Instructions The couplings on the ends of the pre-charged line sets are self-sealing when installed properly. Follow these instructions carefully. It is important that ONLY the nut on the pre-charged tube be turned, or the diaphragms will be torn out by the piercing knives and they will be loose in the refrigeration system. These steps must be performed by an EPA Certified Type II or higher technician. Initial Connections 1.
C1448, C1848, C2148 D Series Remote Condenser Models - User Manual Plumbing Requirements All models require connection to cold, potable water. A hand actuated valve within site of the machine is required. There is a single 3/8” FPT inlet water connection and a single 3/4 FPT drain connection. Water Supply Use field supplied fittings to connect potable water to the water supply connection at the back of the cabinet.
C1448, C1848, C2148 D Series Remote Condenser Models - User Manual Electrical The machine is not supplied with a power cord, the machine must be hard-wired. The dataplate on the back of the cabinet details the power requirements, including voltage, phase, minimum circuit ampacity and maximum fuse size. HACR type circuit breakers may be used in place of fuses. Extension cords are not permitted. Use of a licensed electrician is recommended.
C1448, C1848, C2148 D Series Remote Condenser Models - User Manual Final Check List: 1. Is the unit located indoors in a controlled environment? Open door to access On and Off switch buttons. 2. Is the condenser located where it can receive adequate cooling air? 3. Has the correct electrical power been supplied to the machine? 4. Have all the water supply connections been made? 5. Have all the drain connections been made? 6. Has the remote condenser been properly installed? 7.
C1448, C1848, C2148 D Series Remote Condenser Models - User Manual Initial Start Up 1. Remove front and left side panels. Check machine for any packing or wires rubbing moving parts. Note location of control board in upper left corner of the machine’s front. 2. Switch on the electrical power to the machine. Observe that some of the control’s indicator lights glow and its display shows O. 3. Wait 4 hours for the compressor’s crankcase heater to warm up the oil in the compressor. 4.
C1448, C1848, C2148 D Series Remote Condenser Models - User Manual Adjustments Bridge Thickness - For A Service Tech Only 1/8 - 3/16” bridge 1. Push and hold Off till the machine stops. 2. Remove evaporator cover. 3. Remove left curtain. 4. Use a box wrench and rotate the bridge thickness adjustment screw in 1/8 turn increments CW to increase bridge thickness. 5. Rotate CCW to decrease bridge thickness. Caution: Do not make the bridge too thin or the machine will not harvest properly.
C1448, C1848, C2148 D Series Remote Condenser Models - User Manual Use and Operation Once started, the ice machine will automatically make ice until the bin or dispenser is full of ice. When ice level drops, the ice machine will resume making ice. There are four indicator lights at the front of the machine that provide information on the condition of the machine. Caution: Do not place anything on top of the ice machine, including the ice scoop.
C1448, C1848, C2148 D Series Remote Condenser Models - User Manual Switches The two switches – on and off - can be accessed from the front of the machine. To switch the machine OFF, push and release the Off button. The machine will shut off at the end of the next cycle. Status De-Scale Off r To switch the machine ON, push and release the On button. The machine will go through a start up process and then resume ice making. 02-4294-01 Graphic Rev.
C1448, C1848, C2148 D Series Remote Condenser Models - User Manual Cleaning, Sanitation and Maintenance This ice system requires three types of maintenance: • Remove the build up of mineral scale from the ice machine’s water system and sensors. • Sanitize the ice machine’s water system and the ice storage bin or dispenser. It is the User’s responsibility to keep the ice machine and ice storage bin in a sanitary condition. Without human intervention, sanitation will not be maintained.
C1448, C1848, C2148 D Series Remote Condenser Models - User Manual 11. Wash the sensor and the adjustment screw with ice machine scale remover solution, rinse with clean water. Also wash the water distributor and curtain with the ice machine cleaner solution. Squeeze tabs together, slide out until it stops, then lift to remove. 16. Wash all interior surfaces of the freezing compartment, including evaporator cover and right side panel liner with the sanitizer solution. 17.
C1448, C1848, C2148 D Series Remote Condenser Models - User Manual Remote condenser The condenser fins will need to be cleaned. Push and release the Off button. Wait until the machine stops. Note: Lock out the controller or the ice machine power supply to prevent an unauthorized fan motor restart. If there is imbedded grease, use a commercial coil cleaner to wash out the grease. Dust can be blown out with compressed air from the inside or use a vacuum cleaner and soft brush.
C1448, C1848, C2148 D Series Remote Condenser Models - User Manual What to do before calling for service Reasons the machine might shut itself off: • Lack of water. • Freeze cycle takes too long. • Harvest cycle takes too long. • High discharge temperature. • Controller self test failure. • Very high voltage Check the following: 1. Has the water supply to the ice machine or building been shut off? If yes, the ice machine will automatically restart within 25 minutes after water begins to flow to it.
SCOTSMAN ICE SYSTEMS 775 Corporate Woods Parkway Vernon Hills, IL 60061 800-726-8762 www.scotsman-ice.