Service Manual

C2648 Prodigy and Prodigy Plus Service Manual
January 2015
Page 33
Refrigeration
Refrigerant: R-404A
Charge: 240 ounces
Compressor: Copeland hermetic
Compressor Amps:
Freeze - 13.2 to 12.9, declining to 9.6 at the end of the freeze cycle. 11.6 to 11.9 at ve minutes.
Harvest - 12.7 to 11.8
Expansion valves: Non adjustable, internally equalized, one per evaporator.
Hot gas valves: Pilot operated, line voltage coils. One per plate.
Condenser: Upow type with aluminum coils.
Headmaster: Included with condenser.
Remote Systems: Head pressure control valves in condenser. No check valves. Controller pumps unit down
by closing the liquid line valve and keeping the compressor on for a xed time period at shut down.
High pressure cut out. Shuts compressor off if discharge pressure is too high, automatic reset.
Cut out at 450 PSIG,
Cut in at 350 PSIG.
Evaporators: Unied cell plate. Nickel plated copper. 18” tall.
Small cube = half dice, medium cube = full dice.
Small cube: 7/8" high x 7/8" deep x 3/8" high
Medium cube: 7/8" high x 7/8" deep x 7/8" high