Electrical Shock Hazard
Disconnect electrical
power before beginning
Purge Valve or Water Level Sensor
Purge valve
1. Push and hold the Off button to shut the machine off.
2. Disconnect electrical power.
3. Remove front panel.
4. Unplug wires from valve coil.
Note: The coil can be removed from the valve body
by rotating it 1/8 turn CW. After removal of the coil
the spring and plunger can be taken out.
5. Loosen screws holding valve bracket to mounting
bracket (circled area in photo).
6. Remove inlet and outlet hoses
7. Lift the valve and bracket up and off the keyhole
slots. Remove valve from cabinet.
8. Remove valve from bracket.
9. Reverse to reassemble
10. Push and release the On button to restart the machine
Water level sensor
1. Push and hold the Off button until the machine shuts
off.
2. Remove the front panel.
3. Locate water level sensor.
4. Squeeze the locking tabs together and pull the
sensor up and out of the sump.
5. Unplug the electrical connection from the sensor.
6. Reverse to reassemble.