Owner's Manual

TO INSTALL: Plumbing
Built In Pump Model:
1. Place ice machine in front of installed location.
Adjust leg levelers to approximately correct
position.
2. Remove kickplate and control box cover.
3. Route water inlet line from wall through ice
machine to the front.
4. Locate coil of 3/8" ID plastic drain tubing
secured to the back of the cabinet.
5. Route plastic drain tube from back of cabinet to
drain connection point.
Note: Often an air gap is required by local codes
between the ice machine drain tube and the drain
receptacle.
6. If electrical outlet for ice machine is behind the
cabinet, plug in the ice machine now.
7. Push ice machine into installed position.
8. Cut off water inlet line at required length.
9. Flush water line. Place flare nut on inlet water
line and flare the end of the copper tube.
10. Attach flare nut to the male flare on the inlet
water valve.
11. Turn on the water supply, and make sure that
the ice machine is plugged in and the power is on.
12. Pour a couple of quarts of water into the
storage bin, the drain pump should start and pump
water out. Check for leaks.
13. Replace kickplate and control box cover.
14. Level the cabinet as needed.
ALL PLUMBING MUST MEET LOCAL CODES
DCE33
September 2011
Page 9
THE DCE33 WILL FIT IN A SPACE 15
1
4
"WIDEX33
3
4
" HIGH.
THE DEPTH OF THE CABINET IS 22" TO
THE FRONT EDGE OF THE HANDLE.
Air Gap Device
(Where Required)
Drain
Connection
Water Shut Off
Valve
Water Filter
(Recommended)
Drain Tube From
Back Of Machine
Water Inlet Connection
WATER AND DRAIN
INSTALLATION