Specification Sheet
ERC and PR Remote Condensers
© 2012 Scotsman Ice Systems.
SIS-SS-ERCPR 6-12
Scotsman Ice Systems • 775 Corporate Woods Parkway • Vernon Hills, IL 60061
1-800-SCOTSMAN
Fax: 847-913-9844
E-mail: customer.relations@scotsman-ice.com
www.scotsman-ice.com
39.75
39.75
39.75
39.75
39.75
39.75
39.75
ECC Series
Specifications and design are subject to change without notice.
Model
Number
Overall Length
(in)
Mounting
Hole Spacing
(in)
Depth
(in)
Height
(in)
Basic Electrical
Circuits
Min. Circuit
Ampacity
ECC0800-32A
ECC0800-3A
ECC0800-6A
ECC1410-32A
ECC1410-3A
ECC1200-32A
ECC1800-3A
39.09
39.09
39.09
39.09
39.09
39.09
39.09
27.00
27.00
27.00
27.00
27.00
27.00
27.00
32.06
32.06
32.06
32.06
32.06
32.06
32.06
14.8
10.6
16.8
14.5
9.1
17.8
19
Contains
Headmaster?
Shipping Carton
L x W x H
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Accessories
3BRTE20-EH - 25- ft. insulated line set. Refrigerant and brazing required
3BRTE35-EH - 35 ft. insulated line set. Refrigerant and brazing required
3BRTE50-EH - 50 ft. insulated line set. Refrigerant and brazing required
3BRTE75-EH - 75 ft. insulated line set. Refrigerant and brazing required
KSLT075 - Suction line trap for locating ice maker more than 20 ft. below condenser unit
Operating Requirements: Electrical Voltage Min. -10% Max. +10%
Revit drawings available at
www.scotsman-ice.com
Note: These units are designed to be controlled by the ice machines they are connected to.
208-203/60/1
208-230/60/3
230/50/1
208-230/60/1
208-230/60/3
208-230/60/1
208-230/60/3
Circuit Wires
2
3
2
2
3
2
3
Shipping
Weight
(lb)
41.63” X 33.38” X 45.13”
41.63” X 33.38” X 45.13”
41.63” X 33.38” X 45.13”
41.63” X 33.38” X 45.13”
41.63” X 33.38” X 45.13”
41.63” X 33.38” X 45.13”
41.63” X 33.38” X 45.13”
310
310
310
310
310
310
310
ECC Series Remote Condensing Unit
AIR IN
AIR IN
AIR OUT
2013
SIS-SS-ECC 7-13
Max. Fuse Size
or HACR Circuit
Breaker (amps)
20
15
20
30
20
30
30
SIS-SS-ECC 7-8-2013.indd 2 7/8/2013 12:06:10 PM