Technical Guide

Page 2
New Eclipse Technical Review
Condensing Unit.
The new condensing unit is illustrated below. The ECC0800, ECC1200 and ECC1410 have one condenser
coil, while the ECC1800 has two. The coils are mounted at an angle between the compressor and fan. Airow
is in the side and out the top.
Refrigeration connections are on the side, near the base. The connections are three ball valves with stub
outlets. The ball valves ship closed, the receiver contains the refrigerant charge for the system. Schrader
access valves are on the outside of the ball valves so the interconnecting tubing can be evacuated after
brazing.
The electrical power supply connects to the wires in the junction box near the top of the condensing unit. The
communication cable that connects to the ice making head routes thru a bushing near the base and routes to a
connector on the side of the control box.
Compressor
Dome Pressure
Suction
Pressure
Liquid
Vapor
Suction
Electrical
Junction Box
Coil
Communication
Cable Connection
Location of
Second Coil
Discharge
Pressure