Technical Guide
Page 8
New Eclipse Technical Review
Original Head Size Original Model /Compressor ECC Model / Compressor Replace head?
EH222 800 C0800CP / CS10 ECC0800 / CS10 Use EH222 C
EH222 1000 C1410CP / CS14 ECC1410 / CS14 Use EH222 C
EH330 1200 C1200CP / CS18 ECC1200 / CS18 Use EH330 C
EH430 1400 C1410CP / CS14 ECC1410 / CS14 Use EH430 C
EH430 1800 C1800CP / CS24 ECC1800 / CS24 Use EH430 C
EH430 2000 C2000CP / CS27 no longer available Use EH430 C
CME810 800 CP886 / CS12 - Use EH222, Rewire CP
CME810 1000 CP1086 / CS18 - Use EH222, Rewire CP
CME1386 1300 CP1316 / CS20 - Use EH430, Rewire CP
CME1686 1600 CP1316 / CS20 - Use EH430, Rewire CP
CME2086 2000 CP2086 / Scroll - Replace system
Retrot Information
There may be need to retroft a head with an existing condensing unit. This chart lists the potential
combinations and actions needed.
When Replacing a Head:
Head Size Original Model /Compressor ECC Model / Compressor Replace Condensing Unit?
EH222 800 C0800CP / CS10 ECC0800 / CS10 Use ECC0800
EH222 1000 C1410CP / CS14 ECC1410 / CS14 Use ECC1410
EH330 1200 C1200CP / CS18 ECC1200 / CS18 Use ECC1200
EH430 1400 C1410CP / CS14 ECC1410 / CS14 Use ECC1410
EH430 1800 C1800CP / CS24 ECC1800 / CS24 Use ECC1800
EH430 2000 C2000CP / CS27 no longer available not available
CME810 800 CP886 / CS12 - Use ECC0800, Rewire ECC
CME810 1000 CP1086 / CS18 - Use ECC1410, Rewire ECC
CME1386 1300 CP1316 / CS20 - Use ECC1200, Rewire ECC
CME1686 1600 CP1316 / CS20 - Use ECC1200, Rewire ECC
CME2086 2000 CP2086 / Scroll - Replace system
Rewire CP means adding a transformer to operate the compressor and harvest relays that are in the ice
machine head.
When Replacing a CP or Condensing Unit:
Rewire ECC means removing the transformer that is intended operate the compressor and harvest relays that
are in the EH ice machine head. The transformer to operate the system is in the CME head.
Note: Not all voltages are available to retrot condensing units.