Service Manual

Controller Information
Machine Indicator Lights
·
Power
·
Status
·
Water
·
Clean
Code Display
Main codes - automatically displayed
F Freeze Cycle
F flashes Freeze Cycle is Pending
H Harvest Cycle
H flashes Manual Harvest
b Bin is Full
C Clean Cycle
L Board Locked
d Test Mode
O Off
E Self Test Failed
1 flashesMax Freeze - Retrying
1 Max Freeze Time Shut Down
2 flashes Max Harvest - Retrying
2 Max Harvest Time Shut Down
3 Slow Water Fill
4 High Discharge Temp
5 Sump Temp Sensor Failure
7 Discharge Temp Sensor Failure
8 flashes Short Freeze - Retrying
8 Short Freeze - Thin ice
Setting Codes - requires push button sequence
for access
Water Purge Settings
A, 1, 2, 3, 4, 5
De-scale Interval Settings
6, 5, 3, 3
Prodigy Eclipseä 1200, 1400, 1800, 2000
August 2008
Page 28