Control Switches
There is front access to two switches – On and Off.
To switch the machine OFF, push and release the
Off button. The machine will shut off at the end of
the next cycle. To shut the machine off
immediately, push and hold the Off button for 3
seconds.
To switch the machine ON, push and release the
On button. The machine will go through a start up
process and then resume ice making.
Control Options
There are three optional, field installed controls
that can be added to this machine.
·
VariSmart™ adjustable ice level control
·
Smart-Board™ advanced control board and
data logger
Adjustable ice level control, kit # KVS
When this option is present there is an adjustment
post and an additional indicator light to the right of
the four indicator lights mentioned above. The
ultrasonic ice level control allows the user to
control the point that the ice machine will stop
making ice before the bin or dispenser is full.
Reasons for this include:
·
Seasonal changes in ice used
·
Planning to sanitize the bin
·
Faster turnover for fresher ice
·
Certain dispenser applications where maximum
ice level is not desired
Use of control
There are several positions the ice level can be set
to, including Off (knob and label indicators lined
up), where it fills the bin until the standard bin
control shuts the machine off. See the kit’s
instructions for complete details.
Rotate the adjustment post to the desired ice level.
The machine will fill up to that level and when it
shuts off the indicator light next to the adjustment
post will be On.
Note: Ice will build up in the bin or dispenser at an
angle, the distance set will be from the sensor to
the top of the ice. The sensor position is shown in
the cabinet layout diagrams.
The actual distance between the highest point of
the ice may be closer or further away than the
distance set, depending upon the angle of the ice.