Service Manual

Controller Operation
Control Button Use (from standby)
Set purge level, 1-5 (1 is minimum, 5 is maximum)
or Automatic:
·
Hold off button in for 3 seconds. Release.
·
Press and release the On button to cycle
through and select one of the five purge
settings or to use the Automatic setting.
Recall diagnostic code:
·
Hold off button in for 3 seconds. Release.
·
Press and release the Harvest button to cycle
through each of the last 10 error codes from
most recent to oldest.
Clear diagnostic code:
·
Hold Clean and Harvest buttons in for 3
seconds to clear all prior codes.
Reset control:
·
Depress and release Off, then depress and
release On
Start Test Mode:
·
Hold Off button in for 3 seconds. Release.
·
Hold Clean button in for 3 seconds. Release.
Lock Unlock control:
·
Hold On button in for 3 seconds, keep holding
then press and release Off twice.
Empty reservoir:
·
Hold Clean button in for 3 seconds. Release.
Pump and purge valve will be ON for 30
seconds. Repeat as needed.
Test Mode:
·
Depress Off for 3 seconds, release. Then
depress Clean for 3 seconds.
·
The sump will fill the first 30 seconds of the test.
If the sump is full it will overflow into the bin. At
30 seconds the Water Inlet Valve will shut off
and the Water Pump will turn on. You will be
able to see and hear the water running over the
plates. After 10 seconds the Purge and Vapor
Inlet Valves will turn on. Water will be purging
from the machine. After 10 more seconds the
compressor will start. 5 seconds later the VIV
will close. The compressor will run for a total of
20 seconds. After which everything will turn off
for 5 seconds. After that time the VIV will open
and you’ll be able to hear the hissing as the
pressure is equalized. 10 seconds later the fan
will turn on (if air cooled). After 10 seconds all
will be off and the output test will be complete.
Change De-Scale Notification Interval
Like the others, this feature is accessible only from
standby (Status Light Off).
·
Press and hold harvest button for 3 seconds.
·
This will allow control to enter Time to Clean
Adjustment State.
·
Display current time to clean months on 7
segment display.
·
Pressing clean button repeatedly will cycle
through one of 4 possible settings:
6 months (4380 hours) (default)
5 months (3650 hrs)
4 months (2920 hrs)
3 months (2190 hrs)
Prodigy Eclipseä 1200, 1400, 1800, 2000