Service Manual

14. Locate water level sensor. Squeeze catches
together and pull up to remove sensor. Wash
metal surfaces of sensor with ice machine
cleaner solution.
15. Mix a solution of locally approved sanitizer.
Note; A possible sanitizing solution may be made
by mixing 1 ounce of liquid household bleach with
2 gallons of warm (95-115
o
F.) potable water.
16. Thoroughly wash all surfaces of the ice
thickness sensor, water level sensor, curtain
and water distributor with the sanitizer solution.
17. Thoroughly wash all interior surfaces of the
freezing compartment, including evaporator
frames, back wall, evaporator cover and the
part of the top panel covering the freezing
compartment with the sanitizer solution.
18. Return water level sensor, ice thickness
sensor, water distributors and curtains to their
normal positions.
19. Push and hold the clean button to drain the
reservoir. Push and release the clean button
again and when the flush valve indicator light
goes out, immediately pour the remaining
cleaning solution into the reservoir.
20. Circulate the sanitizer solution for 10 minutes,
then push and release the Clean button.
21. Allow the water system to be flushed of
sanitizer for at least 20 minutes, then push and
release the Off button.
22. Return the evaporator cover and front panel to
their normal position and secure with the
original fasteners.
23. Push and release the On button to resume ice
making.
Other Maintenance
The remote air cooled condenser coil must be
cleaned occasionally to keep the system operating
at high efficiency.
·
Remove any large debris from the outside of the
coil.
·
Vacuum accumulated dust.
·
Wash out the coils with water.
Caution: Do NOT use excessive water pressure as
that will bend the fins.
·
Straighten any damaged fins with a fin comb.
·
If the coils have become coated with grease, a
coil cleaner will have to be used to wash the
coils.
Disconnect power to the condensing unit and
remove the condenser top.
·
Inspect the fan blade to be sure it is not cracked
and is clean.
Return the condenser top to its original position
and reconnect the power supply.
Prodigy Eclipseä 1200, 1400, 1800, 2000
August 2008
Page 39
Moving Parts Hazard
Rotating fan blade can
cause cuts
Disconnect electrical
power before removing
condenser top or fan
guard.
Remove Water Distributor
Squeeze Tabs Together, Slide Out Until it Stops,
Then Lift to Remove
Inspect Orifice Holes
Inspect Water Distributor