Service Manual

Refrigeration System Service
Recovery
Recovery must be done from the condensing unit,
but requires the ice machine to be shut down.
1. At the ice making section, remove the front
panel.
2. Push and release the Harvest button. When the
machine shuts off, recover the refrigerant.
3. Remove compressor package covers.
4. Attach recovery system to low side (compressor
process port valve)
5. If the recovery system can recover liquid, attach
recovery system to high side (receiver liquid line
out valve)
Operate recovery system to remove refrigerant
from the system. No other points of attachment or
solenoid activation are required.
Prodigy Eclipseรค 1200, 1400, 1800, 2000
August 2008
Page 47