User's Manual

EH222 D and Condensing Unit
Remote Low Side Cuber User Manual
October 2014
Page 17
Complete the Installation
After the utilities and refrigeration connections have
been made, secure the unit to the dispenser or bin
top.
Secure ice making section to dispenser or bin
adapter.
Use strap/clips to secure unit:
When used with Cornelius ABS adapter, install
clip on the side of the cabinet. Clip under edge of
adapter and secure to ice making section using
the screws provided in the hardware bag.
Note: If one side will be against a wall, do not use a
clip on that side. One clip is sufcient to secure the
unit.
For use on bin adapter, use clip (as a strap) on
back.
If the ice maker & bin or dispenser is not yet in its nal
position gently move it there.
Note: The refrigerant lines above the machine must
be able to move freely while the machine is being
moved into position.
Final Check List Before Initial Start Up
1. Conrm that the ice making section is installed
indoors in a controlled environment.
2. Conrm that all packing materials have been
removed from all products.
3. Conrm that the ice making section is level.
4. Conrm that all the refrigerant connections have
been made and checked for leaks.
5. Conrm that the proper power supply has been
turned on to the condensing unit.
6. Conrm that cold, potable water has been supplied
to the ice making section and checked for leaks.
7. Conrm that the water supply is adequate.
8. Conrm that there is adequate water pressure and
that any water lters have been checked to conrm
that the cartridges do not need changing.
9. Conrm that the proper size drain tubing has been
installed and properly routed.
10. Conrm that the ice making section has been
connected to the proper power supply.
11. Conrm that the interconnecting wire has been
routed and connected between the ice making section
and the condensing unit.
Clip