Service Manual

Technical Specifications
Ice Making Section (IMS)
Compressor Package
Condenser
* * ERC condenser fan motor is powered from CP
unit and the ERC’s ampacity is included in CP unit
numbers.
Note: The ERC680, ERC1086 and ERC26810 do
NOT contain a headmaster. The headmaster is in
the CP units.
Note: 75 feet of interconnecting control wire (24
volt) is included with the CP units.
Prodigy Eclipseä 600, 800, 1000
February 2008
Page 3
Model Voltage Minimum Circuit
Ampacity
Max Fuse Size Cabinet Size Weight (lb)
EH222SL-1 115/60/1 3 15 22”w x 16.5”d x 29” h 90
EH222ML-1 115/60/1 3 15 same 90
Model Voltage Contains
Headmaster?
Minimum
Circuit
Ampacity
Max
Fuse
Size
Refrigerant
Charge (R-404A)*
(oz)
Cabinet Size Weight
(lb)
C0600CP-32 208-230/60/1 Yes 10 15 232 29 ¾”w x 18”d x 34 ½”h 165
C0600CP-3 208-230/60/3 Yes 7.1 15 232 same 165
C0800CP-32 208-230/60/1 Yes 14.8 20 232 same 180
C0800CP-3 208-230/60/3 Yes 10.58 15 232 same 180
C1410CP-32 208-230/60/1 Yes 16.45 30 272 same 180
C1410CP-3 208-230/60/3 Yes 12.58 20 272 same 180
* Includes entire system charge.
Model Voltage Contains
Headmaster?
Number
of
Circuits
Minimum
Circuit
Ampacity**
Max
Fuse
Size**
Cabinet Size, with legs Weight
(lb)
ERC680-32A 208-230/60/1 No 1 1.25 15 29 ¾”w x 28 5/8”d x 38 ½”h 95
ERC1086-32A 208-230/60/1 No 1 1.25 15 same 95
ER2C6810-32 208-230/60/1 No 2 1.9 15 29 ¾”w x 37 3/16”d x 38 ½”h