This ice machine needs ve types of maintenance:
Air cooled and remote models need their air lters
or condenser coils cleaned regularly.
All models need scale removed from the water
system.
All models require regular sanitization.
All models require sensor cleaning.
All models require a top bearing check.
Maintenance Frequency:
Air lters: At least twice a year, but in dusty or greasy
air, monthly.
Scale removal. At least twice a year, in some water
conditions it might be every 3 months.
Sanitizing: Every time the scale is removed or as
often as needed to maintain a sanitary unit.
Sensor Cleaning: Every time the scale is removed.
Top bearing check: At least twice a year or every time
the scale is removed.
Maintenance: Air lters
1. Pull air lter(s) from panel.
2. Wash the dust and grease off the lter(s).
3. Return it(them) to their original position(s).
Do not operate the machine without the lter in place
except during cleaning.
Maintenance: Air cooled condenser
If the machine has been operated without a lter the
air cooled condenser ns will need to be cleaned.
They are located under the fan blades. The services
of a refrigeration technician will be required to clean
the condenser.
Maintenance: Remote air cooled condenser
The condenser ns will occasionally need to be
cleaned of leaves, grease or other dirt. Check the coil
every time the ice machine is cleaned.
Maintenance: Exterior Panels
The front and side panels are durable stainless steel.
Fingerprints, dust and grease will require cleaning
with a good quality stainless steel cleaner.
Note: If using a sanitizer or a cleaner that contains
chlorine on the panels, after use be sure to wash the
panels with clean water to remove chlorine residue.
Maintenance: Water lters
If the machine has been connected to water lters,
check the cartridges for the date they were replaced
or for the pressure on the gauge. Change cartridges
if they’ve been installed more than 6 months or if the
pressure drops too much during ice making.