Service Manual
N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522
Air, Water or Remote Service Manual
December 2014
Page 35
This ice machine needs ve types of maintenance:
• Air cooled and remote models need their air lters
or condenser coils cleaned regularly.
• All models need scale removed from the water
system.
• All models require regular sanitization.
• All models require sensor cleaning.
• All models require a top bearing check.
Maintenance Frequency:
Air lters: At least twice a year, but in dusty or greasy
air, monthly.
Scale removal. At least twice a year, in some water
conditions it might be every 3 months.
Sanitizing: Every time the scale is removed or as
often as needed to maintain a sanitary unit.
Sensor Cleaning: Every time the scale is removed.
Top bearing check: At least twice a year or every time
the scale is removed.
Maintenance: Air lters
1. Pull air lter(s) from panel.
2. Wash the dust and grease off the lter(s).
3. Return it(them) to their original position(s).
Do not operate the machine without the lter in place
except during cleaning.
Maintenance: Air cooled condenser
If the machine has been operated without a lter the
air cooled condenser ns will need to be cleaned.
They are located under the fan blades. The services
of a refrigeration technician will be required to clean
the condenser.
Maintenance: Remote air cooled condenser
The condenser ns will occasionally need to be
cleaned of leaves, grease or other dirt. Check the coil
every time the ice machine is cleaned.
Maintenance: Exterior Panels
The front and side panels are durable stainless steel.
Fingerprints, dust and grease will require cleaning
with a good quality stainless steel cleaner.
Note: If using a sanitizer or a cleaner that contains
chlorine on the panels, after use be sure to wash the
panels with clean water to remove chlorine residue.
Maintenance: Water lters
If the machine has been connected to water lters,
check the cartridges for the date they were replaced
or for the pressure on the gauge. Change cartridges
if they’ve been installed more than 6 months or if the
pressure drops too much during ice making.
Maintenance