Water
The water supply for ice making must be cold, potable
water. There is a single 3/8” male are potable water
connection on the back panel.
Backow
The design of the oat valve and reservoir prevents
potable water backow by means of a 1" air gap
between the reservoir's maximum water level and the
oat valve water inlet orice.
Drain
There is one ¾” FPT condensate drain tting at the
back of the cabinet.
Tubing
Connect the potable water
supply to the potable water
tting, 3/8” OD copper tubing or
the equivalent is recommended.
Connect the drain tube to the
condensate drain tting. Vent this
drain tube.
Do not Tee ice machine drains
into the drain tube from the ice
storage bin or dispenser. Back
ups could contaminate and
/ or melt the ice in the bin or
dispenser.
Follow all local and national
codes for tubing, traps and air
gaps.