The water supply for ice making must be cold, potable
water. There is a single 3/8” male are potable water
connection on the back panel. Water cooled models
also have a 3/8” FPT inlet connection for the water
cooled condenser. Chilled water can also be used for
this connection.
Drain
There is one ¾” FPT condensate drain tting at the
back of the cabinet. Water cooled models also have a
½” FPT discharge drain connection on the back panel.
Tubing
Connect the potable water supply to the potable water
tting, 3/8” OD copper tubing or the equivalent is
recommended.
Water ltration is recommended. If there is an existing
lter, change the cartridge.
Connect the water cooled water supply to the
condenser inlet.
Note: Do NOT lter water to the water cooled
condenser circuit.
Connect the drain tube to the condensate drain tting.
Connect the water cooled condenser drain tube to the
condenser outlet.
Do not Tee ice machine drains into the drain tube
from the ice storage bin or dispenser. Back ups
could contaminate and / or melt the ice in the bin or
dispenser.
Follow all local and national codes for tubing, traps
and air gaps.