Service Manual
N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522
Air, Water or Remote Service Manual
December 2014
Page 34
Refrigeration System Pressures
Refrigeration system pressures of continuous ow ice machines do not vary a great deal while in operation.
They will vary by model, condenser type and ambient.
70/50 90/70
Model Suction (PSIG) Discharge (PSIG) Suction (PSIG) Discharge (PSIG)
N0422A 37-39 235-245 45-46 255-265
N0422W 38-40 240-250 38-42 240-250
F0522A 37-39 235-245 40-42 250-260
F0522W 37-39 240-250 39-41 240-250
N0622A 28-31 235-245 35-40 275-285
N0622W 29-32 240-250 30-34 240-250
N0622R 35-37 240-250 36-38 250-260
F0822A 28-31 235-245 34-39 285-295
F0822W 29-32 240-250 30-34 240-250
F0822R 35-37 240-250 36-38 250-260
N0922A 22-25 205-215 32-33 280-290
N0922W 22-25 240-250 31-33 240-250
N0922R 28-30 240-250 31-32 245-255
F1222A 22-25 205-215 31-33 280-290
F1222W 22-25 240-250 30-33 240-250
F1222R 28-30 240-250 31-32 245-255
N1322A 22-25 205-215 30-32 295-305
N1322W 26-28 240-250 25-28 240-250
N1322R 29-30 230-240 30-31 245-255
F1522A 22-25 205-215 28-32 295-305
F1522W 26-28 240-250 25-28 240-25
0