Service Manual
Table Of Contents
- Specifications
- Cabinet Layout
- Air flow
- Water Quality
- Door Covering
- Door Panel Attachment
- Custom Panel
- Door swing change
- Installation: Water & Drain
- Gravity Drain
- Electrical
- Cube Size Adjustment
- Harvest Time Adjustment
- Control Settings
- Use
- How to clean the condenser and winterize
- How to remove scale from the ice making system
- System Information
- Water System
- Components
- Controller
- Performance Information
- Refrigeration System
- Thermistor Values
- Service Diagnosis
- Service Diagnosis
- Removal and Repair
- Removal and Repair
- Removal and Repair - Cabinet Removal
- Refrigeration Service
SCCG50 & SCCP50
Service Manual
September 2011
Page 10
Installation: Water & Drain
Water Supply, all models: The recommended water
supply tubing is ¼ inch OD copper. Stainless steel
ex or reinforced PVC tube may also be used.
Install an easily accessible shut-off valve between
the supply and the unit. This shut-off valve should
not be installed behind the unit.
Note: Do not use self-piercing type valves.
1. Remove the front service panel.
2. Route the tubing through the right hole in the
back to the inlet water solenoid valve inlet.
3. Install a compression tting on the tubing and
connect to the inlet of the solenoid.
Drains
There are two types of ice machine models, one
that drains by gravity and one that has an internal
drain pump.
Drain Pump Model drain installation
1. Locate the coil of 3/8” ID plastic drain tubing
secured to the back of the unit.
2. Route the plastic drain tube from the back of
the unit to the drain connection point.
IMPORTANT NOTE: Often an air gap is required
by local codes between the ice maker drain tube
and the drain receptacle.
Screw
Securing
Front Service
Panel
Water Inlet
Connection,
located at the
FRONT of the
machine. Do
NOT connect
to tubing at
the back.
Back View, Drain Pump Model
Drain Tube,
Route to
building drain
Water Inlet
Tube (eld
supplied)