Service Manual

SCCG50 & SCCP50
Service Manual
December 2019
Page 19
System Information A Model
Overall:
Refrigerant: 8 oz R-134a
Compressor: Hermetic, 1300 BTUH
Condenser: Forced draft
Fan blade: 5 blade, 7 inch
Evaporator: Inverted, 24 cube cells. Copper cups
attached to continuous serpentine
Metering device: Cap tube
Defrost method: Hot gas bypass with water
assist
Spray method: 6 water jets
Water charge: 40 ounces
Water valve: 115 volt solenoid, .19 GPM
Water ll time: Varies with harvest time & purge
setting
Spray pump: Pedestal type.
Drain pump: Magnetic drive, controlled by
pressure switch
Purge method: Overow standpipe
Control method: Electronic
Cycle control: Thermistor + timers
Freeze cycle timer A model:10 minutes, + - 4
Freeze cycle timer B model :11 minutes, + - 4
Harvest cycle timer: 20 seconds, + - 40
Cube size adjustment: Freeze timer change.
Harvest cycle adjustment: Harvest timer change
Bin control: Thermostat. Opens on temperature
fall, Cut Out: 35 degrees F. Cut In 45 degrees F.
Range is adjustable.
Electrical Components:
Compressor
Fan motor
Spray pump motor
Drain pump motor
Drain pump switch
Bin light - LED type
Bin light switch - magnetic reed
Inlet water solenoid valve
Hot gas valve
Transformer
Controller
Water sensor
Thermistor
Bin thermostat
Electrical Sequence:
A closed bin thermostat signals to the controller
a need for ice. The controller checks for water,
if water is needed , the controller opens the inlet
water solenoid valve to ll the reservoir. The hot
gas valve is open to equalize the system. When
the reservoir is full, the compressor, fan motor,
water pump are switched on. After 5 seconds the
hot gas valve shuts and ice making begins.
Water is sprayed up into the inverted cup mold.
As the water is cooled and ice begins to form in the
cups, the temperature of the evaporator will fall.
The freeze cycle continues until the temperature
of the thermistor attached to the evaporator outlet
tube falls to about 0°F A model and 3°F B model. At
that point the controller starts a freeze cycle timer,
whose default time is 10 minutes for A model and
11 minutes for B model. At the end of the freeze
cycle’s timed portion the controller switches to the
harvest cycle.
The harvest cycle begins with the controller
stopping the water pump and fan motor. At the
same time it opens the hot gas valve and the
inlet water solenoid valve. The ice is released
by the combination of discharge refrigerant gas
entering the evaporator serpentine and warming
up the copper, plus the inlet water that ows to
the evaporator, oods across the plastic platen to
warm it up and be pre-chilled for the next cycle.
Ice cubes drop individually and harvest continues
until the thermistor attached to the suction line
warms up to about 50°F. At that point
a harvest timer starts, whose default time is
20 seconds. At the end of that time the harvest
cycle ends and the freeze cycle restarts.
Bin control.
The machine’s on and off modes are regulated by a
bin thermostat. The cap tube for the bin thermostat
is in the tube that holds the scoop. The machine
will only begin ice making when the thermostat’s
contacts close. If the contacts re-open before the
temperature of the evaporator drops below a preset
point, the machine will stop. If the temperature
is below that point when the contact s open, the
machine will continue through a complete cycle
and stop at the end of the harvest cycle.