Service Manual

SCCG50 & SCCP50
Service Manual
November 2014
Page 2
Specications
This ice machine is designed to be used indoors,
in a controlled environment. It can be used in a
wide variety of environmental conditions, but there
are limits. Use outside of the listed limitations is
misuse and will void the warranty.
Air temperature limits:
The ice machine will operate adequately within the
limits, but functions best in temperatures between
70 and 80 degrees F.
Minimum – 50 degrees F. (10°C)
Maximum – 100 degrees F. (38°C)
Water temperature limits:
Minimum – 40 degrees F. (4.5°C)
Maximum – 100 degrees F. (38°C)
Water pressure limits:
Minimum – 20 psi (1.4 bar)
Maximum – 80 psi (5.5 bar)
Because the ice machine is making a food product,
the water supply to the ice machine must be
potable, or t for human consumption.
Electrical
115 volt, 60 Hz. Plug into dedicated 15 amp
circuit.
Power consumption: 275 - 400 Watts. Varies
during Freeze and Harvest cycles.
Voltage limits:
Minimum - 104 volts
Maximum – 126 volts
Options:
Door Panel kits: Finished door panels are available
from Scotsman for attachment to the machine,
or a custom panel can be made.
Kit Number Panel Finish Handle Finish
KDFW White White
KDFWS White Stainless Steel
KDFB Black Black
KDFBS Black Stainless Steel
KDFS Stainless Steel Stainless Steel
Kickplate Extension: In some situations the leg
levelers will be extended enough to become visible.
A kit to extend the kickplate over the legs is KKPF.
Cabinet Stability: In some free standing
installations it may be prudent to add a bracket that
secures the back of the cabinet to a wall. That kit
number is KATB.
Drain Conversion:
A gravity drain model can be converted to a drain
pump model by installing a drain pump kit. The
drain pump kit consists of a drain pump, wiring
harness and associated tubing. The kit number is
A39462-021.
Warranty Information
Warranty information is supplied separately from
this manual. Refer to it for coverage. In general,
the warranty covers defects in materials or
workmanship and does not cover corrections of
installation errors or maintenance.
Models: All are air cooled (A series began 8/09):
SCCP50MA-1WU – Pump model, white cabinet - discontinued 2013
SCCG50MA-1WU – Gravity drain model, white cabinet - discontinued 2013
SCCP50MA-1BU – Pump model, black cabinet - discontinued 2013
SCCG50MA-1BU – Gravity drain model, black cabinet - discontinued 2013
SCCP50MA-1SU – Pump model, stainless cabinet, unnished door
SCCG50MA-1SU – Gravity drain model, stainless cabinet, unnished door
SCCP50MA-1SS – Pump model, stainless cabinet and door
SCCG50MA-1SS – Gravity drain model, stainless cabinet and door