Service manual

Technical Characteristics
Typical Cycle Time
16 minutes @ 90
o
F. air and 70
o
F. water; 13 minutes @ 70
o
F. air and 50
o
F. water
Typical Harvest Ice Weight
3.6 pounds .
Typical Low Side Pressure
18-20 PSIG just before harvest
Typical Freeze Cycle Discharge Pressure
190 - 240 PSIG @ 70
o
F. air and 50
o
F. water
250 - 290 PSIG @ 90
o
F. air and 70
o
F. water
250 for water cooled
Refrigerant Charge:
Air cooled = 20 ounces R-502; Water cooled = 19 ounces R-502
Harvest Time
Normally 1
1
2
to 2 minutes. Depends upon time required to warm suction line to 55
o
F.
Typical Suction Pressure, In Harvest:
105 -120 PSIG (@ 75
o
F., may be lower in cooler ambients)
Typical Discharge Pressure, In Harvest:
120 - 150 PSIG
Water Cooled High Pressure Cut Out
Cuts out at 380 PSIG, resets at 315 PSIG
Typical Compressor Amp Draw:
7-8 during freeze cycle; 10-11 during harvest cycle
Compressor:
Copeland: RSN2-0075-PAA
Thermostatic Expansion Valve
Superheat is 3
o
- 6
o
F.
Bin Thermostat
Cut out at 35
o
F., cut in at 39
o
F.. Adjustable warmer.
Ice Size Thermostat:
Switches to harvest cycle with temperature fall to 38oF.. Resets at 43
o
F.
Ice Size Heater
Adds heat to ice size thermostat to prevent premature harvest. 6,000 ohms resistance.
Harvest Termination Thermostat
Opens to switch to freeze cycle with temperature rise to 55
o
F. Resets at 40
o
F.
SLC400
January 1993
Page 18