Service manual

Specifications
Information regarding Model Number, Serial
Number, Ampacity and Maximum Fuse Size are
located on the nameplate of the ice machine. The
model number, serial number and refrigerant
charge are also listed on
the serial number plate
just behind the front
panel.
If recharging, always
use the charge listed on
the ice machine.
Specifications:
The SLC400 will stack onto a
variety of ice storage bins, see
sales literature for proper ice
storage bin.
There is an optional stainless
steel panel kit, SPKSLC, for this
machine.
* Minimum Circuit Ampacity is used to determine
wire size and type per the National Electric Code.
3
3
4
"
1
3
8
"
7
8
"
22"
20"
4
1
4
"
SLC400 Back View
(Air Cooled Model Shown)
Water
Inlet
Drain
Electrical
Inlet
Model Number Dimensions
W" x D" x H"
Condenser
Type
Basic
Electrical
Minimum
Circuit
Ampacity*
Maximum
Fuse Size (or
HACR circuit
breakers)
Refrigerant
Charge. R-502
SLC400AE-1E 22 x 23 x 20 Air 115/60/1 20 20 20 ounces
SLC400WE-1E 22 x 23 x 20 Water 115/60/1 20.8 25 19 ounces
Nameplate
SLC400 Cabinet
Serial Number
Plate
SLC400
January 1993