User's Manual

Page 9 of 12 P/N 595123-01 Rev A 9/07
2. Select “Settings” and “COM Port Selection.” This will open a “Communications Settings” window.
Select the COM Port that was set in Installation. See FIGURE 15.
TO UPDATE THE ID OF A PROPERLY EQUIPPED SCOTT RESPIRATOR
1. Position the SCOTT respirator and the PAK-LINK Computer Interface conveniently close to you
and access to the computer. The PAK-LINK Computer Interface can communicate with an
activated PASS device as far as twenty feet away, so make sure no other units are being
activated in the immediate area.
2. Make sure the SCOTT respirator is OFF and that there is no residual air pressure in the system.
3. Verify that the batteries in the PASS device are good according to the instructions for the PASS
device.
4. On the Control Console on the respirator, press and hold the RESET button for approximately
eight (8) seconds. The lights on the Control Console will flash GREEN and then RED. When the
RED lights begin flashing alternately, the PASS Device is in Transmit Mode. You have
approximately thirty (30) seconds to complete the Update before the PASS Device times-out.
5. Select “Identify Target Device.” After a few seconds, the screen will display a list of the ID
numbers for all units that are in Transmit Mode in the immediate area. Select the ID number for
the unit you wish to Update. See FIGURE 16.
FIGURE 15
TO UPDATE THE RESPIRATOR ID
CONTINUED ON NEXT PAGE...
FIGURE 16