User's Manual

Page 11 of 24
P/N 595264-01 Rev B 06/15
ROTATE COUNTER CLOCKWISE TO LOCK
LOCKED
POSITION
WARNING
ON THE Av-2000 FULL FACEPIECE, vERIFY THAT
THE HEAD HARNESS TABS ROTATE FREELY
AFTER INSTALLATION OF THE MOUNTING
BRACKET. IF THE TABS FAIL TO ROTATE
FREELY, IT MAY RESULT IN A POOR FACEPIECE
TO FACE FIT AND MAY ExPOSE THE USER
OF THE RESPIRATOR TO THE HAZARDOUS
ATMOSPHERES RESULTING IN SERIOUS
INJURY OR DEATH.
INSTALLATION OF THE EPIC 3 RI vOICE AMP ASSEMBLY
The RI VOICE AMP facepiece assembly may be used with any approved SCOTT
respirator which includes a full facepiece equipped with dual voicemitters. Installa-
tion includes pairing the Facepiece assembly with the BLUETOOTH LSM assembly,
mounting the facepiece assembly on the facepiece, connecting the BLUETOOTH LSM
assembly to a portable two-way radio via the cord and radio connector, securing the
BLUETOOTH LSM to the protective gear, and placing the portable two-way radio on
the user’s person.
1. See AUDIO ACCESSORY MOUNTING BRACKET INSTALLATION IN-
STRUCTIONS (P/N 595107-01 closed bracket; P/N 595287-01 open
bracket) for details of attaching the mounting bracket to your SCOTT
full facepiece. Verify that bracket is properly mounted for your SCOTT
full facepiece before proceeding. On the AV-2000 facepiece, pay special
attention to the free movement of the head harness tabs.
NOTE
THE RI VOICE AMP ASSEMBLY WILL ONLY FIT ON AUDIO ACCESSORY BRACKET
P/N 200264-XX AND P/N 200265-XX OR SERVICE KIT BRACKETS P/N 200715-XX,
P/N 200716-XX, AND P/N 201210-XX.
2. The body of the RI VOICE AMP facepiece assembly is keyed so that it
fits in the mounting bracket only one way. Attach the facepiece assembly
to the mounting bracket as follows:
a) Hold the RI VOICE AMP with the battery compartment door facing
the top right harness tab.
b) Align the D-shaped mount on the rear of the amplifier with the open-
ing in the center of the audio accessory bracket and press in.
c) While pressing the Accessory in towards the side of the facepiece
rotate the Accessory 1/4 turn counter clockwise. The lock will make
two (2) “clicks”. The second “click” will lock the accessory into place.
d) To verify that the RI VOICE AMP is properly locked, try to rotate the
accessory clockwise WITHOUT lifting up on the Locking Lever. If the
Accessory will not turn, it is properly locked.
e) A screw is provided in the Locking Lever to prevent accidental re-
moval when mounted on an open bracket. Use a Phillips screwdriver
to tighten the screw snug. Do not over tighten.
INSTALLATION OF THE EPIC 3 RI vOICE AMP
CAUTION
TURN THE FACEPIECE ASSEMBLY CAREFULLY
TO INSTALL. DO NOT FORCE. THE EPIC 3 RI
vOICE AMP SHOULD FIT SNUGLY TO THE
FACEPIECE. IF THE FACEPIECE ASSEMBLY
WILL NOT TURN, CHECK THE ALIGNMENT
AND CONFIRM THAT THE AUDIO ACCESSORY
BRACKET IS PROPERLY INSTALLED.
CAUTION
vERIFY THAT THE PROPER AUDIO ACCESSORY
BRACKET IS INSTALLED ON THE FACEPIECE.
THE EPIC 3 RI vOICE AMP ASSEMBLY WILL
ONLY FIT ON AUDIO ACCESSORY BRACKET P/N
200264-xx AND P/N 200265-xx OR SERvICE KIT
BRACKETS P/N 200715-xx, P/N 200716-xx, AND
P/N 201210-xx.
WARNING
THE COMMUNICATIONS ACCESSORY MUST
BE PROPERLY INSTALLED SO THAT IT DOES
NOT INTERFERE WITH THE OPERATION
OR FIT OF THE FACEPIECE IN ANY WAY.
IMPROPER INSTALLATION MAY RESULT IN A
POOR FACEPIECE TO FACE FIT WHICH MAY
ExPOSE THE USER OF THE RESPIRATOR TO
THE HAZARDOUS ATMOSPHERE LEADING TO
SERIOUS INJURY OR DEATH.
WARNING
WHEN INSTALLING THE COMMUNICATIONS
ACCESSORY, vERIFY THAT THE LATCH
IS FULLY ENGAGED AFTER THE SECOND
“CLICK.” USE THE LOCKING LEvER SCREW
TO SECURE. FAILURE TO vERIFY PROPER
INSTALLATION MAY RESULT IN LOSS OF THE
COMMUNICATIONS ACCESSORY WHICH COULD
LEAD TO SERIOUS INJURY OR DEATH.