When performing the REGULAR OPERATIONAL INSPECTION verify that
the Sensor Module lights are operating as described below:
OPERATION OF SENSOR MODULE LIGHTS
NOTE
THE ORANGE LIGHT IS A COMBINATION OF THE RED, GREEN, AND
WHITE LIGHTS THAT APPEARS ORANGE FROM A DISTANCE. AT
CLOSE RANGE THE INDIVIDUAL LIGHTS MAY BE VISIBLE.
ACTION... SENSOR MODULE LIGHTS WILL…
Start up PASS (Open Cylinder) .............................Bright Light then Flash GREEN
Normal Operation ...................................................Flash GREEN
Respirator Air between 1/2 and 1/3 cylinder .......... Flash ORANGE (two quick ashes) every one (1) second
(available on units manufactured after 09/2015)
Respirator Low air (1/3 cylinder) ............................ Flash ORANGE (alternately)
Low Battery while ON ............................................Flash ORANGE once every two (2) seconds
Shut down .............................................................Lights OFF
Press RESET w/unit OFF (BATTERY TEST) .......Bright Light then:
Flash GREEN if Good/Flash RED if Low
Press MANUAL ALARM with unit OFF .................Flash GREEN then Full Alarm Flash RED
Press RESET from manual alarm .........................Returns to Flash GREEN
PASS Pre-Alarm ...................................................Flash RED (alternately)
PASS Full alarm ..................................................... Flash RED (simultaneously)