User's Manual

Page 21 of 28
P/N 595277-01 Rev E 10/17
WARNING
READ AND UNDERSTAND THE COMPLETE INSTRUCTION MANUAL BEFORE USING A
RESPIRATOR WITH A PAK-ALERT DISTRESS ALARM INSTALLED.
WHEN THE PAK-ALERT
DISTRESS ALARM IS:
IT INDICATES THAT:
Quiet. No lights or sound
Flashing the green light
Flashing the red light and sounding an
ascending/descending tone.
Flashing the red light and sounding a
loud continuous 3 tone chirp
Chirping once every two (2) seconds with
no light ashing
The PAK-ALERT distress alarm is off or
the batteries are used up or removed.
The PAK-ALERT distress alarm is on, in
automatic mode, and monitoring your mo-
tion.
You have not moved in the last twenty (20)
seconds, PAK-ALERT distress alarm will
go into full alarm in twelve (12) seconds or
less if you do not move.
Full alarm: You have not moved in the last
thirty (30) seconds or more or you pushed
the manual alarm button.
The batteries are low. You must put in new
batteries before using the PAK-ALERT
distress alarm again (it will work in low
battery condition long enough to let you
nish the cylinder of air you are on).
QUICK REFERENCE GUIDE TO USE:
WHEN YOU WANT TO: YOU DO: THE PAK-ALERT DISTRESS
ALARM DOES:
Turn it on.
Re-set pre-alarm
Re-set full alarm
Turn it off (nished with use)
Turn on the manual alarm.
Open cylinder valve (cylinder
must have air in it).
Move so that the respirator
moves.
3 quick audible chirps, green
ashing light on control console.
Red ashing light changes to
green, ascending/descending
tone stops.
Loud 3 tone chirp stops, 3 quick
chirps, then red ashing light
changes to green ashing light.
The ashing light goes out and
a fteen (15) second beep se-
quence occurs as the residual air
bleeds off. Unit will sound a two
tone chirp at turn off.
Goes into full alarm, loud 3 tone
chirps from Sensor Module and
bright red ashing light from con-
trol console.
Press re-set button on control
console twice (push, release,
push again).
Close respirator cylinder valve,
open regulator purge valve
letting out all the trapped air,
close regulator purge valve,
press re-set button twice.
Press alarm button on control
console (works whether the
PAK-ALERT distress alarm is
on or off).
DRAFT
NOT FOR DISTRIBUTION