User's Manual

Page 23 of 28
P/N 595277-01 Rev E 10/17
CAUTION
RESPIRATOR SYSTEM MUST NOT BE
PRESSURIZED WHEN BATTERIES ARE BEING
INSTALLED. DAMAGE TO THE ELECTRONIC
COMPONENTS MAY RESULT IF BATTERIES
ARE INSTALLED WITH SYSTEM PRESSURIZED.
SCOTT respirators equipped with the PAK-ALERT distress alarm
require six (6) “AA” cell batteries for operation. The six (6) batteries
power the Heads-Up Display, the PASS device, and the PAK-TRACK-
ER Transmitter. The batteries should be replaced only by a trained
maintenance technician in a clean area known to be nonflammable.
NOTE
WHEN RECEIVING AIR-PAK RESPIRATORS, THE USER SHOULD UP-
DATE THE ELECTRONICS TO THE LOCAL TIME ZONE USING THE
PAK-LINK PROGRAMMER (P/N 200673-01).
Replace batteries as follows:
1. Close respirator cylinder valve, open regulator purge valve letting out
all the trapped air, close regulator purge valve, press the reset button
twice. If there is air pressure left in the system, the green ashing light will
continue to ash while a fteen second beep sequence is heard from the
Sensor Module as the residual air bleeds from the system. As soon as
the air has completely bled from system, the unit will sound a quick two
tone chirp and the PASS DEVICE distress alarm will be inactive. If there
is no pressure in the system when the RESET button is pressed twice,
there will be no beep sequence. If there is air pressure in the system, the
PASS DEVICE distress alarm will return to the active mode.
NOTE
ALWAYS BE SURE THAT CYLINDER VALVE IS OFF AND THE PASS
DEVICE IS COMPLETELY INACTIVE BEFORE CHANGING BATTERIES.
NEVER REMOVE OR REPLACE BATTERIES WITH SYSTEM PRESSUR-
IZED OR DAMAGE MAY OCCUR TO ELECTRONIC COMPONENTS.
2. When replacing batteries on respirators, remove the cylinder and place
the respirator in a clean, non-hazardous area.
3. Use a Phillips driver to remove the Battery Housing Cover as shown in
FIGURE 6. Carefully remove the cover and set aside.
4. Remove used batteries from battery compartment by sliding them out of
the battery compartment.
5. Install six (6) fresh new “AA” batteries of the same type. Always replace
all batteries at the same time.
The battery holder is marked with the style and orientation of the batteries
required. See FIGURE 7.
Use six (6) each of one of the following 1.5 volt AA batteries:
Duracell
2
Alkaline MN1500
Duracell Alkaline MX1500
Duracell Alkaline PC1500
Duracell Quantum QU1500
Energizer
3
Alkaline EN91
Energizer Alkaline E91
Do not mix batteries. Verify correct orientation of batteries as shown on
label inside the battery holder.
WARNING
THE PAK-ALERT DISTRESS ALARM IS INTENDED
TO ASSIST IN LOCATING A PERSON WHO
MAY BE IN A LIFE THREATENING SITUATION.
FAILURE TO FOLLOW THE INSTRUCTIONS FOR
OPENING, CHANGING THE BATTERIES AND
RE-CLOSING THE BATTERY COMPARTMENT
MAY RESULT IN DAMAGE WHICH COULD
CAUSE FAILURE OF THE PASS DURING A LIFE
THREATENING EMERGENCY OR COULD CAUSE
A FIRE OR EXPLOSION IN A FLAMMABLE
OR EXPLOSIVE ATMOSPHERE POSSIBLY
RESULTING IN INJURY OR DEATH.
WARNING
BATTERIES MUST ONLY BE CHANGED IN AN
AREA KNOWN TO BE NONFLAMMABLE.
CHANGING THE BATTERIES IN A FLAMMABLE
ATMOSPHERE MAY CAUSE AN IGNITION
WHICH COULD RESULT IN SERIOUS INJURY
OR DEATH.
BATTERY REPLACEMENT
2
Duracell is a registered trademark of The Procter & Gamble Company, Cincinnati, OH
3
Energizer is a registered trademark of Eveready Battery Company, Inc., St Louis, MO.
WARNING
TO REDUCE THE RISK OF EXPLOSION USE
BATTERIES ONLY FROM THE LIST PROVIDED,
DO NOT MIX OLD BATTERIES WITH UNUSED
BATTERIES, AND DO NOT MIX BATTERIES FROM
DIFFERENT MANUFACTURERS. UNAUTHORIZED
SUBSTITUTION OF COMPONENTS MAY IMPAIR
INTRINSIC SAFETY AND CAUSE AN EXPLOSION
WHICH COULD LEAD TO SERIOUS INJURY OR
DEATH.
FIGURE 6
USE SCREWDRIVER
TO LOOSEN SCREW
AND REMOVE COVER
WARNING
ALWAYS INSTALL THE BATTERIES IN THE
ORIENTATION SHOWN ON THE LABEL. FAILURE
TO PROPERLY INSTALL THE BATTERIES
WILL RESULT IN EITHER REDUCED OR NO
OPERATION OF THE EQUIPMENT WHICH
COULD LEAD TO FAILURE OF THE EQUIPMENT
AND SERIOUS INJURY OR DEATH OF THE
RESPIRATOR USER.
DRAFT
NOT FOR DISTRIBUTION