OPERATION
When switching the system on or off, we advise you to switch on the amplifier last and
switch it off first so as to prevent any impact caused by the ON/OFF switch.
Check whether the local power voltage the same as the one indicated on the back panel
and that all the connections are correct before turning the power on.
Turn the volume adjustment dials for the left and right channels anti-clockwise to the
(- ) position. Before pressing the power supply switch, please switch on the input
signal source. After about 3 seconds, when you hear the relay, turn the volume
adjustment dial for the left and right channels clockwise to the appropriate volume
level. We suggest that you adjust the dial to the maximum (0) position and that you use
the external appliance to adjust the volume level.
When using the amplifier, if the overload pilot lamp (OVERLOAD) blinks, this means
the equipment is working properly and is safe to use. If the overload pilot lamp
(OVERLOAD) no longer blinks, this means the equipment is overloaded. In this case,
please turn down the volume until the indicator blinks again. Please carry follow this
recommendation in order to avoid damaging the equipment by subjecting it to overload
for too long.
About 3 seconds after switching on the equipment, you will hear a muffled sound. If
you hear the same sound when using the amplifier, please switch it off then switch it
back on again after checking the connections. If the problem persists, please consult a
qualified technician or contact our company for maintenance.
GB-8