Remote Monitoring and Configuration
The eyesite 550 can also be accessed, monitored, and configured remotely. The steps
and recommendations are as follows.
To configure remote web server access:
1. Protect the web server by entering a supervisor PIN as described in Chapter 7-
Advanced Options, User Options
2. Create a port forwarding rule in the firewall.
3. Forward from the public address of your firewall to the private address of the
eyesite 550.
4. Because your firewall probably has its own web configuration page on port 80
you will need to choose an unused port.
5. The forwarding rule in this example would be:
Forward inbound data for 62.173.119.215 (the public IP address of the
firewall) port 3000 to 10.10.2.120 (the private IP address of the unit) port 80
(the standard webserver port number).
6. The data type for this forwarding rule is TCP
7. To browse into the web server remotely type:
8. http://62.173.119.215:3000
9. You will be prompted to enter the PIN number you provided before access is
granted.