User's Manual
Screen Service SDT 200UB – SDT 500UB ARK-1 ATSC Operations
July, 2009 v 1.0 Page 3 - 86
Box
Parameter /
Control
Description Admitted Ranges / Values I/A
Input GbE Ch.1/
Ch.2
Format Received transmission format. Not implemented.
• 188 Bytes
• 240 Bytes
A
Input GbE Ch.1/
Ch.2
Lock
Ethernet input lock status indicator. The input Transport Stream is locked when no more than two
consecutive Sync Byte are missed. Not implemented.
• Green: Lock
• Grey: Not locked
A
Input GbE Ch.1/
Ch.2
Sequence
error
Ethernet input Sequence error alarm status. This alarm condition occurs when an error in the
sequence of input packets at IP level occurs. Not implemented.
• Red: Error
• Grey: No errors
A
Input GbE Ch.1/
Ch.2
Overflow
Input GbE overflow alarm status. This alarm condition occurs when the input bitrate exceeds the
capability of the modulation (Ref. to ATSC A/53). Not implemented.
• Red: Alarm on
• Grey: Alarm off
A
Input GbE Ch.1/
Ch.2
RTP Clock RTP packets source clock reference. Not implemented.
• 90 kHz
• 27 MHz
A
Gbe statistic GBE Packets Total amount of good frames received. A