Box
Parameter /
Control
Description Admitted Ranges / Values I/A
Input GbE Ch.1/
Ch.2
Format Received transmission format. Not implemented.
188 Bytes
240 Bytes
A
Input GbE Ch.1/
Ch.2
Lock
Ethernet input lock status indicator. The input Transport Stream is locked when no more than two
consecutive Sync Byte are missed. Not implemented.
Green: Lock
Grey: Not locked
A
Input GbE Ch.1/
Ch.2
Sequence
error
Ethernet input Sequence error alarm status. This alarm condition occurs when an error in the
sequence of input packets at IP level occurs. Not implemented.
Red: Error
Grey: No errors
A
Input GbE Ch.1/
Ch.2
Overflow
Input GbE overflow alarm status. This alarm condition occurs when the input bitrate exceeds the
capability of the modulation (Ref. to ATSC A/53). Not implemented.
Red: Alarm on
Grey: Alarm off
A
Input GbE Ch.1/
Ch.2
RTP Clock RTP packets source clock reference. Not implemented.
90 kHz
27 MHz
A
Gbe statistic GBE Packets Total amount of good frames received. A