User's Manual

Screen Service SDT 200UB – SDT 500UB ARK-1 ATSC Operations
July, 2009 v 1.0 Page 3 - 96
Fan Speed
One of the fans speeds is under the minimum speed level
(1,000 rpm).
I/A
Check fans connections
Verify that fans are not damaged; in this case substitute them.
The substitution can be performed during device normal
operations
0
ITU No SDI Input
Device in ITU470 mode
Selected SDI input not locked.
I
Check input statistics
X (1)
GPS Lock
GPS is selected as frequency reference
GPS communication error alarm is not signaled
GPS signal is not lock.
I/A
Check cable and GPS antenna connections
Hardware fault
X (0)
GPS Communication Error
GPS is selected as frequency reference
Communication errors between ARK ATSC main
board and GPS board.
I/A
Hardware fault
X (0)