User's Manual

Screen Service SDT 200UB – SDT 500UB ARK-1 ATSC Operations
July, 2009 v 1.0 Page 3 - 32
OID Name R\W Description
1.3.6.1.4.1.21678.186.10.9.32 ark1atsc_WarmUpStatus
R
Warm up alarm status
1.3.6.1.4.1.21678.186.11 ark1atsc_Config
1.3.6.1.4.1.21678.186.11.1 ark1atsc_ConfigLoad
W
Load configuration
1.3.6.1.4.1.21678.186.11.2 ark1atsc_ConfigSave
W
Save configuration
1.3.6.1.4.1.21678.186.11.3 ark1atsc_ConfigReset
W
Reset board
1.3.6.1.4.1.21678.186.11.4 ark1atsc_ConfigStandByEnable
RW
LCD stand-by button enable 0: disabled 1:
enabled
1.3.6.1.4.1.21678.186.11.5 ark1atsc_ConfigStandByStatus
R
Current device mode 0: normal 1: standby
1.3.6.1.4.1.21678.186.11.6 ark1atsc_ConfigTime
1.3.6.1.4.1.21678.186.11.6.1 ark1atsc_Year
RW
Year setting (starting from 2000)
1.3.6.1.4.1.21678.186.11.6.2 ark1atsc_Month
RW
Month setting
1.3.6.1.4.1.21678.186.11.6.3 ark1atsc_Day
RW
Day setting
1.3.6.1.4.1.21678.186.11.6.4 ark1atsc_Hour
RW
Hour setting
1.3.6.1.4.1.21678.186.11.6.5 ark1atsc_Minutes
RW
Minutes setting
1.3.6.1.4.1.21678.186.11.6.6 ark1atsc_Seconds
RW
Seconds setting
1.3.6.1.4.1.21678.186.12 ark1atsc_TrapAlarm
Alarm
3.3.5 Configuring alarms masks
The ark1atsc_Alarm leaf allows the monitoring of alarms status, the setting of alarm masks
and thresholds.
Use alarm masks to select how and which alarm have to be notified.