ISO 9001:2000 Cert. N°4500/1 Software User Manual ARK6 External Document Document name: SDT_ARK6_User_Manual_ENG_vATSC Document code: ARK6-UM-000 Author: C. Di Biase Date: September 23rd, 2011 Version: 1.
ISO 9001:2000 Cert. N°4500/1 Table of Contents 1 Document structure ............................................................................................................... 5 2 Scope of the document .......................................................................................................... 6 3 Introduction ........................................................................................................................... 7 3.1 Digitizer features ..........................
ISO 9001:2000 Cert. N°4500/1 5.5.2 DIGITIZER FE Type .................................................................................................. 39 5.5.3 ATSC FE Type ......................................................................................................... 41 5.6 ATSC ............................................................................................................................... 44 5.6.1 ATSC Settings .............................................................
ISO 9001:2000 Cert. N°4500/1 6.2 Idle Menu ..................................................................................................................... 140 6.3 Main Menu ................................................................................................................... 141 6.4 LCD Alarms ................................................................................................................... 142 7 SNMP – Simple Network Management Protocol...........................
ISO 9001:2000 Cert. N°4500/1 1 Document structure This ARK6 User Manual has the following chapters and appendices: Chapter 1 – Document structure. Chapter 2 – Scope of the document. Chapter 3 – Introduction This chapter contains an overview of ARK6 and its features. Chapter 4 – Specifications This chapter lists the ARK6 specifications. Chapter 5 – Java remote graphic user interface. This chapter describes the Java interface provided for board managing.
ISO 9001:2000 Cert. N°4500/1 2 Scope of the document Purpose of this document is to provide a comprehensive description of the functionalities of the SDT Series ARK-6 and to provide operating information on the software elements of the ARK6 system. SDT ARK6 User Manual provides software setup information and includes an overview of Java, SNMP and Local user interfaces. Version 1.
ISO 9001:2000 Cert. N°4500/1 3 Introduction The SDT ARK-6 Series has been designed as a brand new model of software defined transmitters which incorporate all the technical and functional capabilities of the previous models of the ARK-1 family (ARK1, ARK-R, ARK-T, ARK-ATSC, ECHO-2) together with a complete set of new functionalities that bring the transmitter at the forefront of the technology edge.
ISO 9001:2000 Cert. N°4500/1 Table 1.
ISO 9001:2000 Cert. N°4500/1 3.1 Digitizer features Supports the A/D conversion and decoding of NTSC and PAL CVBS inputs Supports 2 CVBS video and 2 L/R audio inputs Adaptive 2-D, 5-line, adaptive comb filter Automatic video standard detection (NTSC/PAL) Automatic video standard switching Luma-peaking with programmable gain 3.2 Satellite receivers features 3.2.1 DVB-S/S2 Input DVB-S and DVB-S2 demodulator that conforms to ETSI EN 300 421 and ETSI TR 102 376 respectively.
ISO 9001:2000 Cert. N°4500/1 3.2.2 DVB-S/S2 plus CAM Input DVB-S and DVB-S2 demodulator that conforms to ETSI EN 300 421 and ETSI TR 102 376 respectively.
ISO 9001:2000 Cert. N°4500/1 3.3 Terrestrial receivers features 3.3.1 ATSC Agile VHF/UHF input Down-conversion (from 50.
ISO 9001:2000 Cert. N°4500/1 3.4 ITU Transmitter features The ARK-6 ITU is an ITU-R BT.470-6 compliant Transmitter. The key features of the ARK-6 ITU are: Standard SDI inputs (SMPTE 259M-C – Component 4:2:2); Agile UHF output Up-converter (from 470 MHz up to 862 MHz). The VHF option is also available. Output adjustable offset frequencies: from -200 kHz to +200 kHz (1 Hz step). 3.4.
ISO 9001:2000 Cert. N°4500/1 3.4.2 ITU Signal Processing Digital audio channels presence and level monitoring. Analog audio sampling rate fixed to 48 kHz. Input redundancy provided by an input autoswitch algorithm based on primary feed presence (SDI and CVBS). Selectable Group Delay curve. Selectable Audio Type. Selectable Sound System. Selectable Emphasis. Adjustable Audio Deviation and Carriers Level. Adjustable White Level, Synchronism Amplitude and Pedes Level. Non-Linear Precorrection.
ISO 9001:2000 Cert. N°4500/1 3.5 ATSC Transmitter features The ARK-6 ATSC is an A/53 and A/153 compliant Transmitter. The key features of the ARK-6 ATSC are: SMPTE-310M with 19.39 Mbps, DVB-ASI (EN-50083/9) and Gigabit Ethernet (PRO-MPEG COP3 R2) inputs; Agile UHF output Up-converter (from 470 MHz up to 862 MHz). The VHF option is also available. Output adjustable offset frequencies: from -200 kHz to +200 kHz (1 Hz step). 3.5.
ISO 9001:2000 Cert. N°4500/1 3.6 System Features Synchronization External or GPS Internal clock Oven Controlled OCXO oscillator (10 MHz and 1 PPS) Output clock 1 PPS and 10 MHz Management Embedded SNMP v1 server Embedded Web server GbE Ports GbE 1: 10/100/1000 Base T Management port GbE 2: 10/100/1000 Base T Data port Security Authentication for GUI access supported. 3.7 Synchronization The ARK6 includes a holdover function provided by a higher grade Oven-Controlled Crystal Oscillator.
ISO 9001:2000 Cert. N°4500/1 4 Specifications 4.1 Input Interfaces ASI/SSI/SDI Number of inputs 4 Connector BNC Zin 75 Ohm Input voltage 800 mVpp (500 to 1200 mVpp) Supported standards CEI EN 50083-9 SMPTE 310M SMPTE 259M TSoIP Number of channels 2 Connector RJ45 Speed 10/100/1000 RF Number of inputs 1 Connector N female Frequency UHF (VHF optional) Level -76 dB to -16 dB Zin 50 Ohm Supported standards It depends on the FE Type. Version 1.
ISO 9001:2000 Cert. N°4500/1 CVBS Number of inputs 2 Connector BNC Zin 75 Ohm Input Voltage 1 Vpp Supported standards PAL NTSC Analog Audio Number of inputs 2 L/R Connector XLR3 (Cannon f) Zin 600 Ohm balanced Input level +6dBm +/- 6 dB Supported standards EIA RF-297-A GPS Number of inputs 1 Connector TNC Zin 50 Ohm Sensitivity -185dBW 10 MHz Number of inputs 1 Connector BNC Zin 50 Ohm Input voltage 2 Vpp Version 1.
ISO 9001:2000 Cert. N°4500/1 1PPS Number of inputs 1 Connector BNC Zin 50 Ohm Input voltage TTL (min 1,7 V) Pulse width 100 us Linear Precorrection Number of inputs 1 Connector SMA Zin 50 Ohm Input level -20 to +11,5 dBm Version 1.
ISO 9001:2000 Cert. N°4500/1 4.
ISO 9001:2000 Cert. N°4500/1 TSoIP Number of channels 2 Connector RJ45 Speed 10/100/1000 Standard PRO-MPEG COP3 R2 ASI Out Monitor Number of outputs 2 Connector BNC Zout 75 Ohm Output voltage 800 mVpp (500 to 1200 mVpp) Supported standards CEI EN 50083-9 SMPTE 310M SMPTE 259M RF Mon Number of outputs 1 Connector SMA Frequency UHF (VHF optional) Level -40 dBm RF Out Zout 50 Ohm 10 MHz Number of outputs 1 Connector SMB Zout 50 Ohm Output voltage 2 Vpp Version 1.
ISO 9001:2000 Cert. N°4500/1 1PPS Number of outputs 1 Connector SMB Zout 50 Ohm Output voltage TTL (min 2,4 V) Pulse width 100 us Version 1.
ISO 9001:2000 Cert. N°4500/1 4.
ISO 9001:2000 Cert. N°4500/1 4.3.1 RS232 pinout Usually personal computers use a standard RS 232 DE-9 connector. Figure 1. DE-9 Male connector Table 2. RS232 DE-9 pinout DE-9 Pin Name Direction Description 2 RXD Receive Data 3 TXD Transmit Data 5 GND - System Ground 4.3.2 TLC pinout ARK6 has a SUB-D 15p Female connector for OPTOs with customized pin assignments. Figure 2. Table 3. Version 1.
ISO 9001:2000 Cert. N°4500/1 4.3.3 TLS pinout ARK6 has a SUB-D 25p Female connector for Relays with customized pin assignments. Figure 3. Table 4. Version 1.
ISO 9001:2000 Cert. N°4500/1 4.4 Power Supply IEC 1 Voltage 80 – 264 VAC Frequency 50 – 60 Hz ARK6 1U Mains Consumption [Test on ch. 21] MODE PWR [dBm] Vac [Volt] Iac[Amp] Consumption [W] ST-BY - 225 0,35 78,8 Power OFF - 225 0,40 90,0 Power ON 21 225 0,62 139,5 Power ON 31 225 0,64 144,0 Power ON 37 225 0,71 159,8 Power ON 41 225 0,80 180,0 ARK6 2U Mains Consumption [Test on ch.
ISO 9001:2000 Cert. N°4500/1 ARK6 3U Mains Consumption [Test on ch. 45] MODE PWR [dBm] Vac [Volt] Iac[Amp] Consumption [W] ST-BY - 225 0,35 78,8 Power OFF - 225 0,40 90,0 Power ON 43 225 2.8 630 Power ON 50 225 4.5 1010 Power ON 53 225 5.7 1280 Power ON 55 225 6.8 1530 Power ON 56 (1) 225 7.4 1660 Note to the table: (1) If required. Version 1.
ISO 9001:2000 Cert. N°4500/1 4.5 Environmental Specification Climatic Temperature range operating 0 °C to +40 °C (+32 °F to +104 °F) Temperature range within specs +5 °C to +45 °C (41 °F to +113 °F) Temperature range storage -30 °C to +70 °C (-22 °F to +158 °F) Humidity operating max 90% RH EMC Compliant to EN50022 (emission) and EN55024 (immunity) Safety Compliant to EN60950-1 RoHs Compliant with directive 2002/95/EC 4.
ISO 9001:2000 Cert. N°4500/1 5 Java Graphic User Interface The Java Graphic User Interface, stored in the board File System, is downloaded to the local PC every time the user connects to the board with a Web Browser. A proper Java Virtual Machine is needed; refer to the Appendix B for a description of supported Java and Internet Browsers. 5.
ISO 9001:2000 Cert. N°4500/1 5.2 Java Menu Bar The following figure shows the menu bar of the Java Graphic User Interface. It allows the switching between control pages that will be described in detail in next chapters. Figure 5. Java menu bar The following controls are provided: System commands bar allows to enable of the following commands: Connect: releases/acquires the connection to the device. Save: saves the device configuration. Load: loads the last saved configuration. Figure 6.
ISO 9001:2000 Cert. N°4500/1 Network: allows to monitor the Network settings of both GbE port 1 and GbE port 2 and to set in/out Ethernet channels parameters. GPS: shows received GPS statistics and provides commands to manage the Holdover functionality. Alarms: provides a grid where to set LCD, Graphic User Interface, Events, Relays, Traps, Input Switch and RF Off alarm masks. Events: shows the board events log and allows the manual setting of date and time. Figure 7.
ISO 9001:2000 Cert. N°4500/1 5.3 Home Page Click on Home Page button, highlighted in the next figure, to access the Home Page. Figure 9. Home Page window The Home Page provides a general description of the equipment, the firmware updating status and a subset of commands here below described: Modes Management: shows the list of all the available modes, identified by their transmission standard, and allows to switch between them. Station Identifier: shows and sets the station name.
ISO 9001:2000 Cert. N°4500/1 5.4 Input Click on Input button, highlighted in the next figure, to monitor the input statistics window. Figure 10. ATSC / DVB-T/T2 Input window The Input window allows to monitor Transport Stream and SDI input statistics and to enable the cable equalizer bypass of each one of them. Version 1.
ISO 9001:2000 Cert. N°4500/1 Table 5. Box Parameter / Control Description ASI Word rate Input word rate. Tuner Word rate Input byte rate. ASI - Tuner Bitrate Input bitrate. ASI - Tuner ASI - Tuner ASI ASI - Tuner Filtered bitrate Format CD Lock Input window Approximately 27 Mword/s Bitrate actually used by the modulator. Format of received TS Packets. ASI Carrier detect. The actual synchronization of the Transport Stream.
ISO 9001:2000 Cert. N°4500/1 Box ASI - Tuner Parameter / Control Overflow Description TS input overflow indicator. This alarm condition occurs when the input bit-rate exceeds the capability of the modulation (Ref. to ETSI EN 302 755). ASI Word Errors Input error rate: word errors per second. Tuner Word Errors Input error rate: Byte errors per second.
ISO 9001:2000 Cert. N°4500/1 Box GbE 2– Channel1/2 GbE 2– Statistics GbE 2– Statistics Parameter / Control Overflow GBE Good Pck GbE Speed Description Input GbE overflow alarm status. This alarm condition occurs when the input bit-rate exceeds the capability of the modulation (Ref. to ETSI EN 302 755). Ethernet connection speed. No duplex information is provided. GBE Bad Pck The number of inbound packets that contained errors. SDI 1/2/3/4 Lock Shows the presence of a valid SDI input stream.
ISO 9001:2000 Cert. N°4500/1 Box SDI 1/2/3/4 Layers Rates Layers Rates Layers Rates Parameter / Control Description Admitted Ranges / Values NTSC 4:2:2 component video; NTSC 4:2:2 16x9 component video; NTSC 4:4:4 13,5 MHz component video; PAL 4:2:2 component video; PAL 4:2:2 16x9 component video; PAL 4:4:4 13,5 MHz component video" Red: Alarm on Used in remux mode only. Grey: Alarm off Layer A/B/C Layer input underflow alarm status.
ISO 9001:2000 Cert. N°4500/1 5.5 Front-End Click on Front-End button, highlighted in the next figure, to access the tuner window. Figure 11. Front-End window Use the Tuner window to monitor input channel, frequency offset, signal level and quality, and to monitor the RF input demodulation parameters. The Tuner window is composed by the following sections: RF power level monitor; Demodulation parameters; Constellation (DVB-T/T2). Tuner window changes on the basis of the Front-End type.
ISO 9001:2000 Cert. N°4500/1 5.5.1 Tuner window: RF power level monitor Box General General General General General General Figure 12. Tuner window: RF power level monitor Table 6. Tuner window: RF power level monitor Parameter / Control Rx Level [dBm] / Progress Bar Low Power Rx Signal High Power Rx Signal Channel Offset [Hz] Bandwidth [MHz] Version 1.
ISO 9001:2000 Cert. N°4500/1 5.5.2 DIGITIZER FE Type This page shows the available statistics for the analog input video. Figure 13. Version 1.
ISO 9001:2000 Cert. N°4500/1 Table 7. Box General CVBS 1/2 input CVBS 1/2 input CVBS 1/2 input CVBS 1/2 input CVBS 1/2 input CVBS 1/2 input Parameter / Control CVBS Inputs: Statistics Description A/D PAL Compensation Enable the PAL compensation on digitized video. This features should be enabled only for particular application e.g. the external ITS insertion in a PAL-M system. Lock General input video signal lock, this is on when the following three signals are locked.
ISO 9001:2000 Cert. N°4500/1 5.5.3 ATSC FE Type The Tuner panel for the ATSC Front-End shows the status of the demodulator, the input modulation parameters and the received signal quality. Figure 14. Version 1.
ISO 9001:2000 Cert. N°4500/1 Table 8. Box General General ATSC RF Input: Status and demodulation parameters Parameter / Control VSB Demod Status Equalyzer Status Version 1.1 Description VSB demodulation status. Equalizer status.
ISO 9001:2000 Cert. N°4500/1 Box Parameter / Control Description General Demodulator Lock Demodulator lock status General Digital AGC Lock Digital AGC lock status. General Frame Lock Indicator General Frame lock status. Carrier Frequency Loop Lock Carrier frequency loop lock status. Timing Frequency Loop Lock Timing frequency loop lock status. General Frequency Offset [kHz] Output carrier offset. General SNR [dB] Signal to Noise Ratio [dB] General SER Segment Error Rate.
ISO 9001:2000 Cert. N°4500/1 5.6 ATSC Click on ATSC button, highlighted in the next figure, to access the ATSC window. Figure 15. ATSC window Use the ATSC Processing page to manage ATSC specific configuration parameters and to monitor output signal level and quality. Version 1.
ISO 9001:2000 Cert. N°4500/1 5.6.1 ATSC Settings Click on the ATSC Settings button, highlighted in the next figure, to access the ATSC general settings. Figure 16. ATSC Processing: ATSC Settings Use the ATSC Settings page to select inputs, to set input/output RF channels, offset frequencies, Frontend and Measure alarm thresholds and to manage Input Autoswitch functionality (refer to Appendix A for further information).
ISO 9001:2000 Cert. N°4500/1 Table 9. Box Parameter / Control ATSC Processing: ATSC Settings Description Input selector. Input Input Input Selector Input Alarm Delay [s] It is not allowed to change input until the Input Autoswitch is enabled. In order to change the primary input, disable the Input Autoswitch functionality, select a different input through the input selector and then enable the Input Autoswitch functionality.
ISO 9001:2000 Cert. N°4500/1 Box Input Autoswitch Input Autoswitch Input Autoswitch Input Autoswitch Tuner Tuner FE Alarm Thresholds Parameter / Control Primary to Secondary Switch Counter Description Primary to secondary input switch countdown expressed in seconds. Secondary to Secondary Switch Counter Secondary to secondary input switch countdown expressed in seconds. Secondary to Primary Switch Counter Secondary to primary input switch countdown expressed in seconds.
ISO 9001:2000 Cert. N°4500/1 Box Parameter / Control Description MEAS Alarm Thresholds SNR Thr [dB] Output Channel Output channel. Output Offset [Hz] Output frequency offset (expressed in Hz). Meas Signal to Noise alarm threshold. Min: 10 Max: 50 Channel ranges are device’s definition dependant. Output Power [dBm] Output power (expressed in dBm). Output Power [W] Output power (expressed in W). Version 1.
ISO 9001:2000 Cert. N°4500/1 5.6.2 ATSC Modulation The ATSC Modulation window allows to select test signals and to manage the M/H mode. Figure 17. Version 1.
ISO 9001:2000 Cert. N°4500/1 Table 10. Box MODULATION Parameter / Control Delete Null Packets TEST M/H M/H M/H M/H REGEN ATSC Processing: ATSC Modulation Description Checked: Enabled Not checked: Disabled None CW Force Null Packets Min: 0 Max: 8191 Grey: M/H mode disabled Green: Alarm OFF. Red: Alarm ON Checked: Enabled Not checked: Disabled Enables/disables the M/H Regeneration mode.
ISO 9001:2000 Cert. N°4500/1 5.6.3 ATSC TVCT The ATSC TVCT window allows to modify On-The-Fly Major and Minor channel numbers associated with the virtual channels defined in the incoming TVCT. If the definition of the current TVCT changes, the version number of the table shall be accordingly modified otherwise the functioning of the facility is not assured. Note: On-The-Fly processing of multi-section TVCTs is not supported. Figure 18.
ISO 9001:2000 Cert. N°4500/1 5.6.4 ATSC Measure Click on Measure button, highlighted in the next figure, to access the measure window. Figure 20. ATSC Processing: ATSC Measure Use the Measure window to monitor output signal level and quality. Refer to ATSC FE Type paragraph for a detailed description of each field within this window. Version 1.
ISO 9001:2000 Cert. N°4500/1 5.6.4.1 ATSC Measure window: RF power level monitor Box General Parameter / Control Monitor Tx Level [dBm] / Progress Bar General General Low Power Tx Signal High Power Tx Signal Version 1.1 Figure 21. ATSC Measure: RF power level monitor Table 11.
ISO 9001:2000 Cert. N°4500/1 5.7 ITU.470 Click on ITU button, highlighted in the next figure, to access the ITU modulator parameters window. Figure 22. ITU window Use the ITU Processing page to manage the configuration of the analog modulator. Version 1.
ISO 9001:2000 Cert. N°4500/1 5.7.1 ITU Settings Click on the ITU Settings button, highlighted in the next figure, to access the ITU general settings. Figure 23. ITU Processing: ITU Settings Use the ITU Settings page to select inputs, to set input/output RF channels, offset frequencies, Frontend and Measure alarm thresholds and to manage Input Autoswitch functionality (refer to Appendix A for further information).
ISO 9001:2000 Cert. N°4500/1 Table 12. Box Parameter / Control ITU Processing: ITU Settings Description SDI 1 Use this control to select one of the available video inputs. CVBS analog inputs are available only when the A/V frontend is available. SDI 2 SDI 3 When and SDI input is selected, the embedded audio channel for that input are modulated and the user can select between channel 1-2 and channel 3-4. When CVBS input is selected the relative analog audio input channels are used.
ISO 9001:2000 Cert. N°4500/1 Box Parameter / Control Description Output power setting. Output Input Autoswitch Input Autoswitch Input Autoswitch Input Autoswitch Input Autoswitch Power [w] Auto Input Enable Actual Input Primary to Secondary Switch Counter This control sets the output power in W. Changing this control will also change the value of power control expressed in dBm. Enables the use of Input Autoswitch finite-state machine. Refer to Appendix A. for further information.
ISO 9001:2000 Cert. N°4500/1 Box Input Autoswitch Parameter / Control State Version 1.
ISO 9001:2000 Cert. N° 5.7.2 ITU Modulation The ITU Modulation window allows actual modulation parameters monitoring and setting. Figure 24. ITU Processing page: ITU Modulation The ITU Modulation window is composed by the following sections: Modulator manager; Test: used to manage RF test modes and Audio-Video test Version 1.
ISO 9001:2000 Cert. N° 5.7.2.1 ITU Modulation: Modulator manager Commands and indicators belonging to this section allow to: Select the video modulation parameters; Set the audio modulation parameters; Set the group delay. Figure 25. Version 1.
ISO 9001:2000 Cert. N°4500/1 Table 13. Box Video Video Video Parameter / Control White Level [%] Synch. Amplitude [%] Pedes Level [%] ITU Modulation: Modulator manager Description Video white level setting. The level value is in percentage upon the synch level. The synch level is taken as 100% reference. Video synch amplitude setting. The level value is in percentage upon the synch level. The synch level is taken as 100% reference. Video pedes level setting.
ISO 9001:2000 Cert. N°4500/1 Box Parameter / Control Description Audio 2 carrier level setting. Audio Carrier Level 2 [dB] MIN: -22 MAX: -7 Step: 1 50us (used for PAL-BG) 75us Audio emphasis enabled (not ticked); This control disables the audio emphasis. Audio emphasis disabled (ticked). Audio modulation type selection. Mono dual carrier; Dual sound; Stereo; Mono single carrier. FM 5.5/5.
ISO 9001:2000 Cert. N°4500/1 5.7.2.2 ITU Modulation: Modulator test controls The following controls enable the testing of RF signal, audio and video. Figure 26. Version 1.
ISO 9001:2000 Cert. N°4500/1 Table 14. Box Test Test Parameter / Control Test mode Video test ITU Modulation: Modulator test modes Description Enables one of the available video test signals. Audio test Enables one of the available audio test signals. Test Tone right [100 Hz] Set the frequency of the right channel test tone. Base unit is 100Hz. Test Tone left [100 Hz] Mute audio enable Version 1.
ISO 9001:2000 Cert. N°4500/1 Box Test Test Test Test Test Test Parameter / Control ITS 0 ITS 1 ITS 2 ITS 3 ITS 4 Enable ITS insert Version 1.1 Description Select the line where to inject the ITS 0 when the enable ITS insert option is enabled. Select the line where to inject the ITS 1 when the enable ITS insert option is enabled. Select the line where to inject the ITS 2 when the enable ITS insert option is enabled.
ISO 9001:2000 Cert. N°4500/1 5.8 Manual compensation 5.8.1 Linear Precorrection Click on Linear Precorrection button, highlighted in the next figure, to access the filter window. Figure 27. Adaptive Linear Precorrection The ARK6 system provides a pre-correction tool for Module&Phase output signal pre-correction. This tool provides two grids for the drawing of: Module of the filter’s curve. Group Delay of the filter’s curve.
ISO 9001:2000 Cert. N°4500/1 In the module grid, the red curve is used to monitor the current module curve calculating and saving. The last saved coefficients are locally downloaded from the FPGA runtime memory registers in order to redraw the curve. Remember to click on the Save as button the first time you change the factory default curves in order to do not overwrite them.
ISO 9001:2000 Cert. N°4500/1 5.8.2 Non Linear Precorrection Click on AM/PM button icon, highlighted in the next figure, to access the pre-correction window. Figure 28. AM/PM Precorrection Two main actions are possible in this section: AM/AM and AM/PM curve drawing: used to change the AM/PM pre-correction coefficient. AM/PM pre-correction files management: used to open or save AM/PM pre-correction setting file. AM/AM and AM/PM curves are specific for each power range of each output channel.
ISO 9001:2000 Cert. N°4500/1 During saving actions one linear pre-correction file is created, the *.dpre file, which contains the digital coefficients for linear pre-correction filter. The following buttons allow the management of non linear pre-correction files and the management of the connection to port 5000: Save: used to save in the device memory the current curves setting.
ISO 9001:2000 Cert. N°4500/1 5.9 Adaptive compensation 5.9.1 Linear Adaptive Precorrection Click on Linear Adaptive Precorrection button, highlighted in the next figure, to access the filter window. Figure 30. Adaptive Linear Precorrection This window provides commands and indicators for adaptive filter management and monitor. The Filter window is organized as follows: Management panel. Complex filter coefficients graph. Module graph. Phase graph.
ISO 9001:2000 Cert. N°4500/1 5.9.1.1 Adaptive Filter The Adaptive Filter provides the ARK6 with an effective adaptive linear compensation. The developed system is responsible for pre-emptively compensating a DVB-T/T2 signal in order to make unimportant the contribution of the system transmission section. The signal passes through the transmission section and re-enters the system as to determine the distortion and the compensating adaptive filter.
ISO 9001:2000 Cert. N°4500/1 5.9.1.2 Adaptive Linear Precorrection: Management panel Table 15. Box Parameter / Control Adaptive Linear Precorrection: Management panel Description General Load Loads filter coefficients from the respective FPGA registers. General Clear Loads flat curve coefficients. General Timeout [s] Once enabled, the adaptive linear compensation has a timeout. When the timeout is expired, the precorrection is stopped.
ISO 9001:2000 Cert. N°4500/1 5.9.1.3 Complex Filter coefficients graph The Complex Filter coefficients graph shows the current coefficients values. The circles indicate the real part of coefficients; the red crosses indicate the imaginary one. Figure 32. Filter window: complex filter coefficients graph 5.9.1.4 Module graph The Module graph shows the actual output signal module according to the complex filer coefficients applied. Figure 33. Filter window: module graph 5.9.1.
ISO 9001:2000 Cert. N°4500/1 5.9.2 Adaptive Non-Linear Precorrection The Non Linear Adaptive Filter provides the ARK6-T2 with an effective adaptive non linear compensation. The developed system is responsible for pre-emptively compensating the signal in order to make unimportant the contribution of the intermodulation products due to the power amplifiers. The signal passes through the power amplifiers and re-enters the system as to determine the distortion and the compensating adaptive filter.
ISO 9001:2000 Cert. N°4500/1 5.9.2.1 Adaptive Non Linear Precorrection: Management panel Table 16. Box Parameter / Control Adaptive Non Linear Precorrection: Management panel Description General Clear Resets the filter coefficients to zero. General ON/OFF Enables the adaptive non linear compensation. General Status Shows the type of adaptive compensation currently used, if any.
ISO 9001:2000 Cert. N°4500/1 5.10 Output Click on Output button, highlighted in the next figure, to access the output window. Figure 36. Output window Use the Output window to change Ethernet, RF and ASI outputs settings, and to monitor all available hardware indicators. ASI Out selectors are used as direct bypass of the specified inputs to ASI OUT HP and ASI OUT LP output interfaces. Version 1.
ISO 9001:2000 Cert. N°4500/1 Table 17. Box General Parameter / Control RF ON / OFF Output window Description Output RF signal enabling. The possible output RF signal status are the following: ON; RF OFF: automatic switch off of the output signal (refer to Amplifier status); Clock Frequency reference Actual Freq. Ref.
ISO 9001:2000 Cert. N°4500/1 Box Status Parameter / Control PS 26V [V] Description Min: 24V Max: 28V Max: 8A Min: 45V Max: 55V Max: 18A Min: 45V Max: 55V Third PSU current indicator, expressed in Ampere, for SDTx501 devices.
ISO 9001:2000 Cert. N°4500/1 Box Parameter / Control Description Alarm OFF: an alarm switched off the amplifier RF OFF: amplifier manually set to off Opto OFF: output RF is switched off by an optocoupler Change mode: the amplifier is automatically switched off during the mode switch (e.g. T1 / T2) 10. Missing file OFF: the amplifier is automatically switched off because of the lack of *.cdef and *.def files (additional files will be included in future releases). 11.
ISO 9001:2000 Cert. N°4500/1 Box Parameter / Control Status Fan 2 Status Fan 3 Status Fan 4 Description Fan 2 speed indicator (values are expressed in rpm). Used in SDTx20, SDTx50, SDTx201 and SDTx501. Fan 3 speed indicator (values are expressed in rpm). Used in SDTx20, SDTx50, SDTx201 and SDTx501. Fan 4 speed indicator (values are expressed in rpm). Used in SDTx501. Shows the status of the CPU fan.
ISO 9001:2000 Cert. N°4500/1 Box Opto & Relay Parameter / Control Relay 0…3 Description Green: Alarm on/Mode A/RF Off Grey: Alarm off/Mode B/RF On Green: Closed (0) Grey: Opened (1) Switch mode Opto status indicators. When the Switch mode is set to Opto: Green: Closed (0) Closed (0): Switch to mode B Grey: Opened (1) Opened (1): Switch to mode A Green: Closed (0) Grey: Opened (1) Relays status indicators. RF Off Opto status indicators.
ISO 9001:2000 Cert. N°4500/1 Box General Parameter / Control Offset [Hz] Description Output frequency offset (expressed in Hz). General Power [dBm] Output power (expressed in dBm). General Power [W] Output power (expressed in W). General Bandwidth [MHz] The output channel bandwidth. FWD Power Thresholds Warning [dB] Forward power warning threshold expressed in dB. FWD Power Thresholds Alarm [dB] Forward power alarm threshold expressed in dB.
ISO 9001:2000 Cert. N°4500/1 Box GbE 2 ch1/2 Tx GbE ch1/2 Out Parameter / Control Input Status Version 1.1 Description It selects which TS input shall be re-transmitted on RTP output channel 1. This selection is totally independent from the selection of the TS input to the modulator. Ethernet transmission on channel 1 status indicator.
ISO 9001:2000 Cert. N°4500/1 Box Parameter / Control Description Admitted Ranges / Values ASI Out 1/2 Input o ASI 1 o ASI 2 Digital modes: o ASI 3 Selects which Transport Stream shall be re-proposed on ASI OUT HP/LP output. o ASI 4 o Tuner 1 (if present) o Tuner 2 (if present) Analog modes: o GbE 2 ch1 Selects which SDI input shall be re-proposed on ASI OUT HP/LP output.
ISO 9001:2000 Cert. N° 5.10.1 Reflex Power Management The ARK6 is provided with a reflex power control logic that prevents the amplifier stage from being permanently damaged. Figure 37. Reflex Pwr Management If the output reflex power goes over its alarm threshold, the amplifier stage is automatically shut down and the system reacts to this situation on the basis of the user selectable “Number of attempts”.
ISO 9001:2000 Cert. N°4500/1 Table 18. Box Parameter / Control Reflex Pwr Management Number of attempts Reflex Pwr Management Current number of attempt Reflex Pwr Management Status Output window: Reflex Pwr Management Description The number of attempts to restore the system after RFL power has gone over the alarm threshold. The current number attempt to restore the system. It shows the current status of the Reflex Power.
ISO 9001:2000 Cert. N°4500/1 5.11 Network Click on Network button, highlighted in the next figure, to access the Network management window. Figure 38. Network window This window allows the Network management on both PRO-MPEG COP 3 RX and TX sides. It also allows the monitoring of the board IP and MAC addresses. Note: The Clock Recovery Function, used in MFN transmissions of received streams on Ethernet channels 1 and/or 2, is based on the timestamps of incoming packets.
ISO 9001:2000 Cert. N°4500/1 Table 19. Box Parameter / Control Network window Description GbE 1/2 General Settings / Network IP address Gbe port 1 / 2 IP address. GbE 1/2 General Settings / Network MAC address Gbe port 1 / 2 MAC address. GbE 1/2 General Settings / Network Gateway Gbe port 1 / 2 Gateway address. GbE 1/2 General Settings / Network Netmask Gbe port 1 / 2 Netmask. GbE 2 General Settings / Network IGMP Enable Enables the IGMP protocol.
ISO 9001:2000 Cert. N°4500/1 Box Parameter / Control Description Admitted Ranges / Values GbE 2 ch1/2 Rx GbE 2 ch1/2 Rx GbE 2 ch1/2 Rx GbE 2 ch1/2 Rx GbE 2 ch1/2 Rx GbE 2 ch1/2 Rx GbE 2 ch1/2 Rx GbE 1 / 2 Statistic GbE 1 / 2 Statistic Protocol Bitrate Filtered bitrate Format Lock Overflow RTP Clock GbE Good Pck GbE Speed Version 1.1 Ethernet input packets protocol. UDP/RTP: o Green: Detected o Grey: Not detected Bit-rate of TS from Ethernet input.
ISO 9001:2000 Cert. N°4500/1 Box Parameter / Control Description GbE 1 / 2 Statistic GbE Bad Pck The number of inbound packets that contained errors. Community Get Read community setting. Community Set Set community setting. Community Trap Trap community setting. GbE 2 ch1/2 Tx Enable send frame Channel 1/2 Ethernet transmission enabling. GbE 2 ch1/2 Tx IP Channel 1/2 Ethernet transmission IP address.
ISO 9001:2000 Cert. N°4500/1 Box GbE 2 ch1/2 Tx GbE 2 ch1/2 Tx GbE 2 ch1/2 Tx GbE 2 ch1/2 Tx Parameter / Control TS Pck per Frame Frame type TS Format RTP Clock Version 1.1 Description Number of packets per frame. Transmission protocol selector. Transmission format. RTP packets clock reference.
ISO 9001:2000 Cert. N°4500/1 5.12 GPS Click on GPS button, highlighted in the next figure, to access the GPS received statistics window. Figure 39. Version 1.
ISO 9001:2000 Cert. N°4500/1 Table 20. Box Parameter / Control GPS window Description General GPS Software Version The firmware version of the GPS module. Satellite #Number of Visible sat Number of visible GPS satellites indicator. Satellite #Number of Tracked sat Number of tracked GPS satellites indicator. Satellite Ublox GPS Lock Ublox GPS Lock status. This LED shows the GPS lock status derived from live data provided by the GPS receiver through a proprietary protocol.
ISO 9001:2000 Cert. N°4500/1 5.12.1 Holdover Management The ARK6 includes a holdover function provided by a higher grade Oven-Controlled Crystal Oscillator. Figure 40. Holdover Management The ARK6 is equipped with an internal OCXO for improved phase noise and stability. The system is provided with internal 10MHz and 1PPS signals which are disciplined to the GPS time signal or to the 10MHz and 1PPS external references. The stability of internal frequency and phase is assured by the highly stable OCXO.
ISO 9001:2000 Cert. N°4500/1 4. 5. Version 1.1 Holdover ON Condition: if the OCXO is no more locked to the selected frequency reference and the Holdover function is enabled and available, the equipment enters into holdover mode. Associated event: “Holdover ON”. Holdover TMO Expired Condition: the Holdover state is “Holdover ON” (the function is enabled) and the Holdover timeout period elapses prior to regain the lock of the selected clock reference source.
ISO 9001:2000 Cert. N°4500/1 Table 21. Box General GPS window: Holdover Management Parameter / Control Fine Frequency Adjust Description Internal frequency reference fine tuning setting. It is possible to increase and decrease the frequency offset of the OCXO with reference to the 10MHz clock by 1/21 Hz steps using the Fine Frequency Adjust.
ISO 9001:2000 Cert. N°4500/1 Box OCXO OCXO OCXO OCXO OCXO Parameter / Control GPS Lock Tracking SFN Ready Holdover Ready Holdover Holdover Management Holdover Enable Holdover Management Holdover Timeout [h] Holdover Management Status Version 1.1 Description OCXO locked to the external GPS reference. It shows whenever the OCXO is not locked to the selected frequency reference or not.
ISO 9001:2000 Cert. N°4500/1 Box Holdover Management Parameter / Control Timeout Status Version 1.1 Description The countdown of the Holdover timeout.
ISO 9001:2000 Cert. N° 5.13 Alarms Click on Alarms button, highlighted in the next figure, to access the alarms management window. Figure 41. Alarms window The Alarms window allows the setting of alarm masks and the monitoring of alarms status. Use alarm masks to select how and which alarm have to be notified. Masks are organized in columns. The twelve columns represent twelve destinations of each alarm notification: GUI: the selected alarms status is notified on the Java alarm page icon.
ISO 9001:2000 Cert. N°4500/1 Table 22. Alarm Temperature Absolute High Temperature Alarm (3dB) Temperature Warning Alarms window Description and limitations Troubleshooting Case temperature over 75°C, the maximum endurable limit. Temperature level goes over the alarm threshold. The output power is consequently lowered by 3 dB (always within the admitted power range).
ISO 9001:2000 Cert. N°4500/1 Alarm Description and limitations Troubleshooting GPS signal is not locked by either the OCXO or the GPS receiver. GPS Not Locked The monitoring of this alarm is disabled when GPS is not used as clock reference or when the GPS Communication Error is raised.
ISO 9001:2000 Cert. N°4500/1 Alarm 10MHz Not Locked Description and limitations *.cfg *.jar *.drlin *.def *.ochf *.pwr2 *.fpga6 *.sav *.snmp *.cdef2 *.htm *.gpsf Troubleshooting Reload the file system If the frequency reference is Internal: OCXO fault If the frequency reference is External: 10 MHz is not locked. Version 1.
ISO 9001:2000 Cert. N°4500/1 Alarm 1PPS Not Locked Description and limitations Troubleshooting If the frequency reference is Internal: OCXO fault If the frequency reference is External: 1PPS is not locked to the selected frequency reference. FPGA Boot alarm FPGA boot has not been successfully completed.
ISO 9001:2000 Cert. N°4500/1 Alarm PS Voltage Out Of Range PS Current Out Of Range Description and limitations Troubleshooting Power Supply voltage out of range. This alarm is risen when at least one of the following conditions is met: PS 26V < 24V or > 28V PS1/PS2 50V < 45V or > 55V Power Supply current out of range.
ISO 9001:2000 Cert. N°4500/1 Alarm [DVB-T2] Input Overflow Description and limitations Troubleshooting Selected TS input overflow. Check the capability of the current modulation scheme Check if the configuration has been loaded Mode(2) RF mask (1) T2 X [DVB-T2] FE Not Locked Logical AND between FE TS lock and FE demodulator ready (SyncStat equals to 6). Check input signal and cable T2 X [DVB-T2] FE Squelch Front-End Squelch level goes over the alarm threshold.
ISO 9001:2000 Cert. N°4500/1 Alarm Description and limitations Troubleshooting [DVB-T2] MEAS MER Low Measure MER goes under the alarm threshold. [DVB-T2] MEAS Signal Quality Low Measure Signal Quality goes under the alarm threshold.
ISO 9001:2000 Cert. N°4500/1 Alarm [DVB-T2] MEAS LDPC Mean Err Description and limitations Troubleshooting RF output LDPC iteration per minute goes over the alarm threshold. Mode(2) RF mask (1) Check input signal T2 0 Check input signal T2 X Check connection status of physical input associated to logic input One or both Seamless logic input of the current mode isn’t locked.
ISO 9001:2000 Cert. N°4500/1 Alarm Description and limitations Troubleshooting Mode(2) RF mask (1) T 0 T 0 T X T X Seamless improper working warning An error has been detected on Logical seamless input.
ISO 9001:2000 Cert. N°4500/1 Alarm Description and limitations Troubleshooting Mode(2) RF mask (1) T 1 T X T 1 MIP packets missing. This alarm’s RF OFF mask should always be enabled. Alarm raising limitations: Check input signal Check 1PPS Hardware fault Seamless improper working warning Check cable connections This alarm is high when the Network delay is greater than the Maximum delay or when the internal counter, used to compute the System delay is not locked to 1PPS.
ISO 9001:2000 Cert. N°4500/1 Alarm Description and limitations Troubleshooting Mode(2) RF mask (1) [DVB-T] FE MER Low Front-End MER goes under the alarm threshold. Check input signal and cable T X [DVB-T] FE Signal Quality Low Front-End Signal Quality goes under the alarm threshold. Check input signal and cable T X [DVB-T] MEAS Not Locked Logical AND between Meas TS lock and Meas demodulator ready (SyncStat equals to 6).
ISO 9001:2000 Cert. N°4500/1 Alarm Description and limitations Troubleshooting Mode(2) RF mask (1) ITU X ITU X [ISDB-T] Input Error ISDB-T X [ISDB-T] IIP Modulation Error ISDB-T X ISDB-T X [ISDB-T] System delay ISDB-T X [ISDB-T] IIP SFN error ISDB-T X [ISDB-T] Network delay ISDB-T X ISDB-T X [ITU] Input Wrong Standard Selected Input video standard (525 or 625 lines) not compatible with the ARK6 definition standard.
ISO 9001:2000 Cert. N°4500/1 Alarm [ISDB-T] Rate error Layer B [ISDB-T] Rate error Layer C [ISDB-T] Table Overflow Layer A [ISDB-T] Table Overflow Layer B [ISDB-T] Table Overflow Layer C Description and limitations Troubleshooting The layer Rate alarm is on when the layer input bitrate is over/under the expected bitrate. Expected bit-rate depends on modulation parameter setting The layer Rate alarm is on when the layer input bitrate is over/under the expected bitrate.
ISO 9001:2000 Cert. N°4500/1 Alarm Description and limitations Troubleshooting [ISDB-T] MEAS MER Layer A Measure MER goes under the alarm threshold. [ISDB-T] MEAS MER Layer B Measure MER goes under the alarm threshold. [ISDB-T] MEAS MER Layer C Measure MER goes under the alarm threshold. [ISDB-T] MEAS PreViterbi BER High Layer A Measure Pre-Viterbi BER goes over the alarm threshold. [ISDB-T] MEAS PreViterbi BER High Layer B Measure Pre-Viterbi BER goes over the alarm threshold.
ISO 9001:2000 Cert. N°4500/1 Alarm Description and limitations Troubleshooting Mode(2) RF mask (1) [ISDB-T] FE MER Layer B Front-End MER goes over the alarm threshold. Check input signal and cable ISDB-T X [ISDB-T] FE MER Layer C Front-End MER goes over the alarm threshold. Check input signal and cable ISDB-T X [ISDB-T] FE PreViterbi BER High Layer A Front-End Pre-Viterbi BER goes over the alarm threshold.
ISO 9001:2000 Cert. N°4500/1 Alarm Description and limitations Troubleshooting Mode(2) RF mask (1) [ATSC] MEAS SNR Low Measure SNR goes under the alarm threshold. Check the configuration ATSC 0 [ATSC] FE Demodulator Not Locked ATSC demodulator of the Front-End board not locked. Check input signal ATSC X [ATSC] FE SNR Low Front-End SNR goes under the alarm threshold. Check input signal ATSC X [ATSC] No TVCT Input TVCT table not present.
ISO 9001:2000 Cert. N°4500/1 5.14 Events Click on Events button, highlighted in the next figure, to access the events windows. Figure 42. Events window Open the Events window to slide the events list. Events are reported with the following information: Time: event detection time. Date: event detection date. Type: type of event: Version 1.1 o Alarm; o Command; o Event; o System Init.
ISO 9001:2000 Cert. N°4500/1 Each event type is characterized by a different colour, the following list explain the mean of each colour: Red: alarm (refer to alarms list in Alarms paragraph and to Alarms list table); Green: command (See ARK6_SW_Reference manual_v1_0.
ISO 9001:2000 Cert. N°4500/1 Description-Event PS Restart N PS OFF Restart Amp. from OPTO Event Description This event is reported when one of the following alarms is raised: PS1/2 50V voltage out range PS1/2 50V current out of range The fourth time one of the preceding alarms is raised the amplifier is restarted (from 1 up to 4 times). N: number of amplifier restarting. Only in SDTX 201 and 501 versions.
ISO 9001:2000 Cert. N°4500/1 Description-Event In. AUTO switch to string Forced = mode Event Description When Input Select Mode is set on Autoswitch and the selected input is not locked the device switch to the next available locked input (refer to Task Error Event paragraph) and this event is generated. string: ASI1 ASI2 ASI3 ASI4 Tuner RxCh1 RxCh2 If the device is in Mode A and the selected working mode is disabled by default (as established in the MODE_DIS field of the *.
ISO 9001:2000 Cert. N°4500/1 Description-Event Save drlin err: xx Event Description An error occurs during saving linear precorrection coefficients. xx: error code: 0x80: File system busy; 0x01: New *.drlin file opening error; 0x02: number of coefficients information writing error; 0x03: linear coefficients writing error; 0x07: File date writing error; 0x08: Old *.
ISO 9001:2000 Cert. N°4500/1 Description-Event Holdover OFF Holdover SFN Ready Holdover Ready Holdover ON Holdover TMO Expired Fan N Speed string Event Description Condition 1: the clock reference is changed and the OCXO is not locked yet. Condition 2: the input clock reference is not present. The OCXO is locked to the selected frequency reference and the system is waiting for the OCXO stabilization. Condition 1: the OCXO is stable and the Holdover function is now available.
ISO 9001:2000 Cert.
ISO 9001:2000 Cert. N°4500/1 Alarm Description-Alarm [DVB-T2] MEAS MER Low Meas MER Low [DVB-T2] MEAS Signal Quality Low Meas S.Quality Low [DVB-T2] T2-MI Err T2-MI Err [DVB-T2] T2-MIP Err T2-MIP Err [DVB-T2] Holdover Holdover [DVB-T2] PPS Phase PPS Phase [DVB-T2] Configuration Not Loaded Cfg.
ISO 9001:2000 Cert. N°4500/1 Alarm Description-Alarm [DVB-T] MEAS SNR Low Meas SNR Low [DVB-T] MEAS MER Low Meas MER Low [DVB-T] MEAS Signal Quality Low Meas S.
ISO 9001:2000 Cert.
ISO 9001:2000 Cert. N°4500/1 5.14.1 Date and Time Setting The upper part of the event window shows the actual time and date and allows the manual setting of those parameters. Figure 43. Time and date setting Click to each part of the date and time to change the parameter and then increase or decrease its value with the up/down arrows.
ISO 9001:2000 Cert. N°4500/1 TASK Description Bit WD_TCP_IP_TASK This task implements the TCP-IP protocol stack. 4 WD_TIMER_TICK_TASK This task generates the clock for the TCP-IP task. 5 WD_STV0362_TASK This task gathers information from both the HP and LP tuners and configures them.
ISO 9001:2000 Cert. N°4500/1 5.14.4 System Initialization Event At every system initialization the event System Init is generated. This event is followed by 25 bytes specifying type and specific code of errors occurred during system initialization. Each byte refers to an error as described in the following table: Table 26. Init system event specific data Description FS_ERR File System error. INFO_ERR *.cfg file error. DEF_ERR *.def file error. LCD_ERR LCD error. PLL_960M_ERR 960 MHz PLL error.
ISO 9001:2000 Cert. N°4500/1 Description CALIB_ERR *.pwr file error. Errors code 0x00: File ok. 0x01: Current AGC mode file not found. 0x02: Current AGC mode file open error. 0x03…0x12: Invalid current AGC mode file (syntax error). 0x20: Other AGC mode file not found 0x21: Other AGC mode file open error. 0x22…0x26: Invalid other AGC mode file (syntax error). Byte 9° Please note that the AGC mode may be analog or digital. Actual AGC mode is displayed in Java output window.
ISO 9001:2000 Cert. N°4500/1 Description CH_DEF_ERR *.cdef file error. Version 1.1 Errors code 0x00: File ok. 0x01: File not found. 0x02: File open error. 0x03: syntax error or lack of input number of channels. 0x13: syntax error or lack of output number of channels. 0x04: input channels memory allocation error. 0x14: output channels memory allocation error. 0x05: when the automatic indexing of channels listed in *.
ISO 9001:2000 Cert. N°4500/1 5.15 System menu Figure 44.
ISO 9001:2000 Cert. N°4500/1 5.15.2 View Menu Figure 46. View menu The View menu allows accessing the following windows: Home Page Input Front-End ISDB-T Processing ITU Processing DVB-T Processing ATSC Processing DVB-T2 Processing Linear Precorrection AM/PM Precorrection Adaptive Linear Precorrection Adaptive Non Linear Precorrection Output Network. GPS. Alarms Events: Events window. Options...: Options window. Version 1.
ISO 9001:2000 Cert. N°4500/1 5.15.2.1 Options window The Options window has two tabs: Time: Time Read Interval [s]; Alerts: the selection of events to display. Click on the Save button to save Java options; a new *.properties file will be created. The device is not loaded with a factory default *.properties file, but it is created and then stored in System File once properties are saved for the first time. 5.15.2.1.1 Time Figure 47.
ISO 9001:2000 Cert. N°4500/1 The selection is performed among the following types of event: Commands (blue boxes): o Gigabit Ethernet commands; o RS232 commands; o SNMP commands; o LCD Display commands. Alarms (red boxes); Events (green messages): o Board events. Typing error (yellow messages): o Typed setting is incorrect. Click on hide button to close alerts popup windows. Figure 49.
ISO 9001:2000 Cert. N°4500/1 5.15.3 Help Menu Figure 50. Help menu The Help menu allows to select one of the following options: Contents: Help with an abstract of the User Manual. About: shows the board name and the management IP address. It also provides uC, FPGA, Java and GPS software versions. Click on OK button to close the window. Figure 51. Version 1.
ISO 9001:2000 Cert. N°4500/1 Info: shows serial numbers of HW components, File System content and the managed system characteristics. Click on OK button to close Info window. Figure 52. Figure 53. Figure 54. Version 1.
ISO 9001:2000 Cert. N°4500/1 5.16 Download Software Standalone The Download Software Standalone button allows the downloading of standalone Java application (executable *.jar file) based on java applet. If your browser is Internet Explorer, it may block the site from downloading files to your computer.
ISO 9001:2000 Cert. N°4500/1 6 Local User Interface The following paragraphs describe the local user interface for ARK6 T2. This user interface is composed of LCD Display, seven buttons and two status LEDs. Here below is depicted the ARK6 Front Panel. ESCAPE ON ALARM STANB-BY OK LEFT ARROW RIGHT ARROW UP ARROW DOWN ARROW STAND-BY: push this button (lie in wait for two seconds) to put the equipment on STAND-BY mode. The orange led lights up and the written STAND-BY MODE appears on the display.
ISO 9001:2000 Cert. N°4500/1 6.1 Boot and Welcome Message Turning on the equipment, the display shows the progress bar as follow: Screen Service ARK - DVB-T2 System Init Init : [ Screen Service ARK - DVB-T2 Start system Init : [ ] ] Wait Screen Service ARK - DVB-T2 Boot FPGA Init : [ ] Wait Wait Screen Service ARK - DVB-T2 Start system Init : [ ] Ready When the boot is over, the device is ready. Screen Service ARK - DVB-T2 Start system Init : [ Screen Service ARK - DVB-T2 IP 10.77.98.
ISO 9001:2000 Cert. N°4500/1 6.2 Idle Menu ARK - DVB-T2 In:ASI1 Out 17.1dBm CH:22 UTC: 14:11 10/03/11 This menu appears after one minute waiting from the last touch. Information contained in the Idle Menu are described in next table. Table 27. Local User Interface: Idle Menu Information Description ARK – DVB-T2 (ATSC) Device description In Input signal source Out Output power and channel IP Management IP address (GBE 1) UTC UTC time and date Press ESC to enter the MAIN MENU. Version 1.
ISO 9001:2000 Cert. N°4500/1 6.3 Main Menu Events Network setup Time & Date setup / / OK: SET This menu shows six SUBMENUs. It is possible to view them sliding the menu up and down, with the UP or DOWN ARROWS, and to select one of them by pushing OK button. Submenus contained in the Main Menu are described in next table. Table 28.
ISO 9001:2000 Cert. N°4500/1 6.4 LCD Alarms Through the LCD Alarms mask it is possible to select which alarm has to be notified on LCD display. When an alarm condition occurs the alarm button is lighted and an alarm message is displayed in the Alarms submenu. The following table lists alarms to alarm messages association (refer to Alarms paragraph for further information about alarms and their masks). Table 29. Alarms descriptions list Alarm Alarm Message Temperature Absolute High Temp.
ISO 9001:2000 Cert.
ISO 9001:2000 Cert. N°4500/1 7 SNMP – Simple Network Management Protocol The SNMP model assumes the existence of managers and agents. A manager is a software module in a management system responsible for managing the device. An agent is a software module in a managed device responsible for maintaining local management information and delivering that information to a manager via SNMP. A management information exchange can be initiated by the manager (via polling) or by the agent (via trap).
ISO 9001:2000 Cert. N°4500/1 7.1 SNMP Protocol Preferences Go to SNMP Protocol Preferences. The following parameters should be set in order to correctly configure the SNMP Manager: SNMP protocol version: SNMPv1/SNMPv2; Read Community: the same of the one set in the Get field of Java interface, community section; Set Community: the same of the one set in the Set field of Java interface, community section; Timeout [s]: user defined; Retransmits: user defined; Port number: 161.
ISO 9001:2000 Cert. N°4500/1 7.2 Monitoring All status and setup information can be queried via SNMP. To get the setup and status information you need a management system (or a special MIB browser). Next figure, referring to MG-SOFT MIB Browser as an example, is a broad view of the ARK6 tree structure. Figure 57. Version 1.
ISO 9001:2000 Cert. N°4500/1 The SSBT MIBs are: ssbt-common-types: the MIB module housing SSBT Textual Conventions. ssbtAtscModulation: the MIB module to manage the equipment configuration when operated in ATSC mode. ssbtClock: the MIB module for clock management. ssbtArk6Atsc: the specific ARK6-ATSC MIB. ssbtGps: the MIB module to monitor the collection of live data from the GPS receiver. ssbtHwMonitor: The MIB module for HW monitor.
ISO 9001:2000 Cert. N°4500/1 Table 30. OID ARK6 SNMP Tree Structure Name R/W 1 1.3 1.3.6 1.3.6.1 1.3.6.1.2 1.3.6.1.2.1 1.3.6.1.2.1.1 iso org dod internet mgmt mib-2 system 1.3.6.1.2.1.1.1 sysDescr R 1.3.6.1.2.1.1.2 1.3.6.1.2.1.1.3 1.3.6.1.2.1.1.4 1.3.6.1.2.1.1.5 1.3.6.1.2.1.1.6 1.3.6.1.2.1.1.7 1.3.6.1.4 1.3.6.1.4.1 1.3.6.1.4.1.21678 1.3.6.1.4.1.21678.302 1.3.6.1.4.1.21678.302.1 1.3.6.1.4.1.21678.302.1.1 1.3.6.1.4.1.21678.302.1.2 1.3.6.1.4.1.21678.302.1.3 1.3.6.1.4.1.21678.303 1.3.6.1.4.1.21678.
ISO 9001:2000 Cert. N°4500/1 OID 1.3.6.1.4.1.21678.303.2.3.1 1.3.6.1.4.1.21678.303.2.4 utcDate gpsLockStatus R 1.3.6.1.4.1.21678.303.2.4.1 glsGps R GPS lock status derived from live data provided by the GPS receiver 1.3.6.1.4.1.21678.303.3 1.3.6.1.4.1.21678.303.3.1 1.3.6.1.4.1.21678.303.3.2 1.3.6.1.4.1.21678.303.3.3 1.3.6.1.4.1.21678.303.3.3.1 1.3.6.1.4.1.21678.303.3.3.2 1.3.6.1.4.1.21678.303.3.3.3 1.3.6.1.4.1.21678.303.4 1.3.6.1.4.1.21678.303.4.1 1.3.6.1.4.1.21678.303.4.2 1.3.6.1.4.1.21678.303.4.
ISO 9001:2000 Cert. N°4500/1 OID 1.3.6.1.4.1.21678.306.5.2.1.2 1.3.6.1.4.1.21678.306.5.2.1.3 1.3.6.1.4.1.21678.306.5.2.1.4 1.3.6.1.4.1.21678.306.6 fansDescr fansMeasUnit fansSpeed temperatures R R R 1.3.6.1.4.1.21678.306.6.1 tempNumber R 1.3.6.1.4.1.21678.306.6.2 1.3.6.1.4.1.21678.306.6.2.1 1.3.6.1.4.1.21678.306.6.2.1.1 1.3.6.1.4.1.21678.306.6.2.1.2 1.3.6.1.4.1.21678.306.6.2.1.3 1.3.6.1.4.1.21678.306.6.2.1.4 1.3.6.1.4.1.21678.306.7 1.3.6.1.4.1.21678.306.7.1 1.3.6.1.4.1.21678.306.7.2 1.3.6.1.4.1.
ISO 9001:2000 Cert. N°4500/1 OID 1.3.6.1.4.1.21678.307.1.2 1.3.6.1.4.1.21678.307.1.2.1 1.3.6.1.4.1.21678.307.1.2.2 1.3.6.1.4.1.21678.307.1.2.3 Name isT2InputAutoswitch ist2iaEnable ist2iaState ist2iaActualInput RW R R 1.3.6.1.4.1.21678.307.1.2.4 ist2iaPrimaryToSecondaryCounter R 1.3.6.1.4.1.21678.307.1.2.5 ist2iaSecondaryToSecondaryCounter R 1.3.6.1.4.1.21678.307.1.2.6 ist2iaSecondaryToPrimaryCounter R 1.3.6.1.4.1.21678.307.1.3 1.3.6.1.4.1.21678.307.1.3.1 1.3.6.1.4.1.21678.307.1.3.1.1 1.3.6.1.
ISO 9001:2000 Cert. N°4500/1 OID Name R/W 1.3.6.1.4.1.21678.307.1.4.3.2.1.3 istsssaPatCrcEn RW 1.3.6.1.4.1.21678.307.1.4.3.2.1.4 istsssaMipCrcEn RW 1.3.6.1.4.1.21678.307.1.4.3.2.1.5 istsssaSyncErrEn RW 1.3.6.1.4.1.21678.307.1.4.3.2.1.6 istsssaPktJitterEn RW 1.3.6.1.4.1.21678.307.1.4.3.2.1.7 istsssaTransportErrEn RW 1.3.6.1.4.1.21678.307.1.4.3.2.1.8 istsssaAsiWordErrEn RW 1.3.6.1.4.1.21678.307.1.4.3.2.1.9 istsssaMipPriorityErrEn RW 1.3.6.1.4.1.21678.307.1.4.3.2.1.10 1.3.6.1.4.1.
ISO 9001:2000 Cert. N°4500/1 OID 1.3.6.1.4.1.21678.307.1.7.3 isaiaActualInput R 1.3.6.1.4.1.21678.307.1.7.4 isaiaPrimaryToSecondaryCounter R 1.3.6.1.4.1.21678.307.1.7.5 isaiaSecondaryToSecondaryCounter R 1.3.6.1.4.1.21678.307.1.7.6 isaiaSecondaryToPrimaryCounter R 1.3.6.1.4.1.21678.307.1.8 1.3.6.1.4.1.21678.307.1.8.1 1.3.6.1.4.1.21678.307.1.8.2 1.3.6.1.4.1.21678.307.1.9 1.3.6.1.4.1.21678.307.1.9.1 1.3.6.1.4.1.21678.307.1.9.2 1.3.6.1.4.1.21678.307.1.9.
ISO 9001:2000 Cert. N°4500/1 OID 1.3.6.1.4.1.21678.307.2.3.1 1.3.6.1.4.1.21678.307.2.3.2 1.3.6.1.4.1.21678.307.2.3.2.1 1.3.6.1.4.1.21678.307.2.3.2.1.1 1.3.6.1.4.1.21678.307.2.3.2.1.2 1.3.6.1.4.1.21678.307.2.3.2.1.3 1.3.6.1.4.1.21678.307.2.3.2.1.4 1.3.6.1.4.1.21678.307.2.3.2.1.5 Name sdiNumber sdiTable sdiEntry sdiIndex sdiDescr sdiLock sdiCarrierDetectAlarm sdiCh12Present R/W R NA 1.3.6.1.4.1.21678.307.2.3.2.1.6 sdiCh1Level R 1.3.6.1.4.1.21678.307.2.3.2.1.7 sdiCh2Level R 1.3.6.1.4.1.21678.307.2.3.
ISO 9001:2000 Cert. N°4500/1 OID 1.3.6.1.4.1.21678.307.3.1.3 1.3.6.1.4.1.21678.307.3.1.4 1.3.6.1.4.1.21678.307.3.1.5 1.3.6.1.4.1.21678.307.3.1.6 1.3.6.1.4.1.21678.307.3.1.7 1.3.6.1.4.1.21678.307.3.1.8 1.3.6.1.4.1.21678.307.3.1.9 1.3.6.1.4.1.21678.307.3.1.10 1.3.6.1.4.1.21678.307.3.1.11 1.3.6.1.4.1.21678.307.3.1.12 1.3.6.1.4.1.21678.307.3.1.13 1.3.6.1.4.1.21678.307.3.1.14 1.3.6.1.4.1.21678.307.3.1.15 1.3.6.1.4.1.21678.307.3.2 1.3.6.1.4.1.21678.307.3.2.1 1.3.6.1.4.1.21678.307.3.2.2 1.3.6.1.4.1.21678.307.3.2.
ISO 9001:2000 Cert. N°4500/1 OID 1.3.6.1.4.1.21678.307.3.2.23 1.3.6.1.4.1.21678.307.3.2.24 1.3.6.1.4.1.21678.307.3.3 1.3.6.1.4.1.21678.307.3.3.1 1.3.6.1.4.1.21678.307.3.3.2 1.3.6.1.4.1.21678.307.3.3.3 1.3.6.1.4.1.21678.307.3.3.4 1.3.6.1.4.1.21678.307.3.3.5 1.3.6.1.4.1.21678.307.3.3.5.1 1.3.6.1.4.1.21678.307.3.3.5.2 1.3.6.1.4.1.21678.307.3.3.5.2.1 1.3.6.1.4.1.21678.307.3.3.5.2.1.1 1.3.6.1.4.1.21678.307.3.3.5.2.1.2 1.3.6.1.4.1.21678.307.3.3.5.2.1.3 1.3.6.1.4.1.21678.307.3.3.6 1.3.6.1.4.1.21678.307.3.3.6.1 1.
ISO 9001:2000 Cert. N°4500/1 OID 1.3.6.1.4.1.21678.307.3.3.7.2.1.12 1.3.6.1.4.1.21678.307.3.3.7.2.1.13 1.3.6.1.4.1.21678.307.3.3.7.2.1.14 1.3.6.1.4.1.21678.307.3.3.7.2.1.15 1.3.6.1.4.1.21678.307.3.3.7.2.1.16 1.3.6.1.4.1.21678.307.3.3.7.2.1.17 1.3.6.1.4.1.21678.307.3.3.7.2.1.18 1.3.6.1.4.1.21678.307.3.3.7.2.1.19 1.3.6.1.4.1.21678.307.3.3.7.2.1.20 1.3.6.1.4.1.21678.307.3.3.7.2.1.21 1.3.6.1.4.1.21678.307.4 1.3.6.1.4.1.21678.307.4.
ISO 9001:2000 Cert. N°4500/1 OID 1.3.6.1.4.1.21678.307.5 1.3.6.1.4.1.21678.307.5.1 1.3.6.1.4.1.21678.307.5.1.1 1.3.6.1.4.1.21678.307.5.1.2 1.3.6.1.4.1.21678.307.5.1.3 1.3.6.1.4.1.21678.307.5.1.4 1.3.6.1.4.1.21678.307.5.1.5 1.3.6.1.4.1.21678.307.5.1.6 1.3.6.1.4.1.21678.307.5.1.6.1 1.3.6.1.4.1.21678.307.5.1.6.2 1.3.6.1.4.1.21678.307.5.1.6.3 1.3.6.1.4.1.21678.307.5.1.6.4 1.3.6.1.4.1.21678.307.5.2 1.3.6.1.4.1.21678.307.5.2.1 1.3.6.1.4.1.21678.307.5.2.2 1.3.6.1.4.1.21678.307.5.2.3 1.3.6.1.4.1.21678.307.5.2.4 1.
ISO 9001:2000 Cert. N°4500/1 OID 1.3.6.1.4.1.21678.307.6.2 1.3.6.1.4.1.21678.307.6.2.1 1.3.6.1.4.1.21678.307.6.2.2 1.3.6.1.4.1.21678.307.6.2.2.1 1.3.6.1.4.1.21678.307.6.2.2.1.1 1.3.6.1.4.1.21678.307.6.2.2.1.2 1.3.6.1.4.1.21678.307.6.2.2.1.3 1.3.6.1.4.1.21678.307.6.2.2.1.4 1.3.6.1.4.1.21678.307.6.2.2.1.5 1.3.6.1.4.1.21678.307.6.2.2.1.6 1.3.6.1.4.1.21678.307.6.2.2.1.7 1.3.6.1.4.1.21678.307.6.2.2.1.8 1.3.6.1.4.1.21678.307.6.2.2.1.9 1.3.6.1.4.1.21678.307.6.2.2.1.10 1.3.6.1.4.1.21678.307.7 1.3.6.1.4.1.21678.
ISO 9001:2000 Cert. N°4500/1 OID 1.3.6.1.4.1.21678.308.1.6 imsEWS 1.3.6.1.4.1.21678.308.1.6.1 imsewsEnable RW 1.3.6.1.4.1.21678.308.1.6.2 1.3.6.1.4.1.21678.308.1.7 1.3.6.1.4.1.21678.308.1.7.1 1.3.6.1.4.1.21678.308.1.7.2 1.3.6.1.4.1.21678.308.1.7.2.1 1.3.6.1.4.1.21678.308.1.7.2.1.1 1.3.6.1.4.1.21678.308.1.7.2.1.2 1.3.6.1.4.1.21678.308.1.7.2.1.3 1.3.6.1.4.1.21678.308.1.7.2.1.4 1.3.6.1.4.1.21678.308.1.7.2.1.5 1.3.6.1.4.1.21678.308.2 1.3.6.1.4.1.21678.308.2.1 1.3.6.1.4.1.21678.308.2.2 1.3.6.1.4.1.21678.
ISO 9001:2000 Cert. N°4500/1 OID 1.3.6.1.4.1.21678.308.3.5 1.3.6.1.4.1.21678.308.3.5.1 1.3.6.1.4.1.21678.308.3.5.2 1.3.6.1.4.1.21678.308.3.5.2.1 1.3.6.1.4.1.21678.308.3.5.2.1.1 1.3.6.1.4.1.21678.308.3.5.2.1.2 1.3.6.1.4.1.21678.308.3.5.2.1.3 1.3.6.1.4.1.21678.308.3.5.2.1.4 1.3.6.1.4.1.21678.308.3.5.2.1.5 1.3.6.1.4.1.21678.308.3.5.2.1.6 1.3.6.1.4.1.21678.308.4 1.3.6.1.4.1.21678.308.4.1 1.3.6.1.4.1.21678.308.4.2 1.3.6.1.4.1.21678.308.4.3 1.3.6.1.4.1.21678.308.4.4 1.3.6.1.4.1.21678.308.4.5 1.3.6.1.4.1.21678.
ISO 9001:2000 Cert. N°4500/1 OID Name 1.3.6.1.4.1.21678.309.2.3 itumasCarrierLevel1 RW 1.3.6.1.4.1.21678.309.2.4 itumasCarrierLevel2 RW 1.3.6.1.4.1.21678.309.2.5 1.3.6.1.4.1.21678.309.2.6 1.3.6.1.4.1.21678.309.3 1.3.6.1.4.1.21678.309.3.1 1.3.6.1.4.1.21678.310 1.3.6.1.4.1.21678.310.1 1.3.6.1.4.1.21678.310.1.1 1.3.6.1.4.1.21678.310.1.1.3 1.3.6.1.4.1.21678.310.1.1.
ISO 9001:2000 Cert. N°4500/1 OID Name R/W Description Output frequency offset expressed in Hz (from -200 kHz up to 200 kHz) 1.3.6.1.4.1.21678.310.1.1.7.2 osomioRfFreqOff RW 1.3.6.1.4.1.21678.310.1.1.8 1.3.6.1.4.1.21678.310.1.1.8.1 osomAOutput osomaoRfChannel RW 1.3.6.1.4.1.21678.310.1.1.8.2 osomaoRfFreqOff RW 1.3.6.1.4.1.21678.310.1.1.9 1.3.6.1.4.1.21678.310.1.1.9.1 osomItuOutput osomituoRfChannel RW 1.3.6.1.4.1.21678.310.1.1.9.2 osomituoRfFreqOff RW 1.3.6.1.4.1.21678.310.1.1.9.3 1.3.6.
ISO 9001:2000 Cert. N°4500/1 OID 1.3.6.1.4.1.21678.310.3.2.1 1.3.6.1.4.1.21678.310.3.2.1.1 1.3.6.1.4.1.21678.310.3.2.1.2 1.3.6.1.4.1.21678.310.3.2.1.3 1.3.6.1.4.1.21678.310.3.3 1.3.6.1.4.1.21678.310.3.3.1 1.3.6.1.4.1.21678.310.3.3.1.1 1.3.6.1.4.1.21678.310.3.3.2 1.3.6.1.4.1.21678.310.3.3.2.1 1.3.6.1.4.1.21678.310.3.3.2.2 1.3.6.1.4.1.21678.310.3.3.2.3 1.3.6.1.4.1.21678.310.3.3.2.4 1.3.6.1.4.1.21678.310.3.3.3 1.3.6.1.4.1.21678.310.3.3.3.1 1.3.6.1.4.1.21678.310.3.3.3.2 1.3.6.1.4.1.21678.310.3.3.3.3 1.3.6.1.4.
ISO 9001:2000 Cert. N°4500/1 OID 1.3.6.1.4.1.21678.311.1.3.1.5 1.3.6.1.4.1.21678.311.2 1.3.6.1.4.1.21678.311.2.1 1.3.6.1.4.1.21678.311.2.2 1.3.6.1.4.1.21678.311.2.3 1.3.6.1.4.1.21678.311.2.3.1 1.3.6.1.4.1.21678.311.2.3.1.1 1.3.6.1.4.1.21678.311.2.3.1.2 1.3.6.1.4.1.21678.311.2.3.1.3 1.3.6.1.4.1.21678.311.2.3.1.4 1.3.6.1.4.1.21678.311.2.3.1.5 1.3.6.1.4.1.21678.311.2.3.1.6 1.3.6.1.4.1.21678.311.2.3.1.7 1.3.6.1.4.1.21678.311.2.3.1.8 1.3.6.1.4.1.21678.311.2.3.1.
ISO 9001:2000 Cert. N°4500/1 OID Name 1.3.6.1.4.1.21678.313.1.9 t2msAutoRfLoop 1.3.6.1.4.1.21678.313.1.10 1.3.6.1.4.1.21678.313.1.10.1 1.3.6.1.4.1.21678.313.1.10.2 1.3.6.1.4.1.21678.313.1.10.3 1.3.6.1.4.1.21678.313.1.10.4 1.3.6.1.4.1.21678.313.1.10.5 1.3.6.1.4.1.21678.313.2 1.3.6.1.4.1.21678.313.2.1 1.3.6.1.4.1.21678.313.2.2 1.3.6.1.4.1.21678.313.2.2.1 1.3.6.1.4.1.21678.313.2.2.2 1.3.6.1.4.1.21678.313.2.2.3 1.3.6.1.4.1.21678.313.2.2.4 1.3.6.1.4.1.21678.313.2.2.5 1.3.6.1.4.1.21678.313.2.2.6 1.3.6.1.4.1.
ISO 9001:2000 Cert. N°4500/1 OID 1.3.6.1.4.1.21678.313.2.2.7 1.3.6.1.4.1.21678.313.2.2.8 1.3.6.1.4.1.21678.313.2.2.9 1.3.6.1.4.1.21678.313.2.2.10 1.3.6.1.4.1.21678.313.2.2.11 1.3.6.1.4.1.21678.313.2.2.12 1.3.6.1.4.1.21678.313.2.2.13 1.3.6.1.4.1.21678.313.2.2.14 1.3.6.1.4.1.21678.313.2.2.15 1.3.6.1.4.1.21678.313.2.2.16 1.3.6.1.4.1.21678.313.2.2.17 1.3.6.1.4.1.21678.313.2.2.18 1.3.6.1.4.1.21678.313.2.2.19 1.3.6.1.4.1.21678.313.2.2.20 1.3.6.1.4.1.21678.313.2.2.21 1.3.6.1.4.1.21678.313.2.2.22 1.3.6.1.4.1.
ISO 9001:2000 Cert. N°4500/1 OID 1.3.6.1.4.1.21678.313.2.3.6.2.1.2 1.3.6.1.4.1.21678.313.2.3.6.2.1.3 1.3.6.1.4.1.21678.313.2.3.7 1.3.6.1.4.1.21678.313.2.3.7.1 1.3.6.1.4.1.21678.313.2.3.7.2 1.3.6.1.4.1.21678.313.2.3.7.2.1 1.3.6.1.4.1.21678.313.2.3.7.2.1.1 1.3.6.1.4.1.21678.313.2.3.7.2.1.2 1.3.6.1.4.1.21678.313.2.3.7.2.1.3 1.3.6.1.4.1.21678.313.2.3.7.2.1.4 1.3.6.1.4.1.21678.313.2.3.7.2.1.5 1.3.6.1.4.1.21678.313.2.3.7.2.1.6 1.3.6.1.4.1.21678.313.2.3.7.2.1.7 1.3.6.1.4.1.21678.313.2.3.7.2.1.8 1.3.6.1.4.1.21678.
ISO 9001:2000 Cert. N°4500/1 OID 1.3.6.1.4.1.21678.313.3.1.8 1.3.6.1.4.1.21678.313.3.1.9 1.3.6.1.4.1.21678.313.3.1.10 1.3.6.1.4.1.21678.313.3.1.11 1.3.6.1.4.1.21678.313.3.1.12 1.3.6.1.4.1.21678.313.3.1.13 1.3.6.1.4.1.21678.313.3.1.14 1.3.6.1.4.1.21678.313.3.1.15 1.3.6.1.4.1.21678.313.3.1.16 1.3.6.1.4.1.21678.313.3.1.17 1.3.6.1.4.1.21678.313.3.1.18 1.3.6.1.4.1.21678.313.3.1.19 1.3.6.1.4.1.21678.313.3.1.20 1.3.6.1.4.1.21678.313.3.1.21 1.3.6.1.4.1.21678.313.3.1.22 1.3.6.1.4.1.21678.313.3.1.23 1.3.6.1.4.1.
ISO 9001:2000 Cert. N°4500/1 OID 1.3.6.1.4.1.21678.313.3.2.6.2.1.3 1.3.6.1.4.1.21678.313.3.2.7 1.3.6.1.4.1.21678.313.3.2.7.1 1.3.6.1.4.1.21678.313.3.2.7.2 1.3.6.1.4.1.21678.313.3.2.7.2.1 1.3.6.1.4.1.21678.313.3.2.7.2.1.1 1.3.6.1.4.1.21678.313.3.2.7.2.1.2 1.3.6.1.4.1.21678.313.3.2.7.2.1.3 1.3.6.1.4.1.21678.313.3.2.7.2.1.4 1.3.6.1.4.1.21678.313.3.2.7.2.1.5 1.3.6.1.4.1.21678.313.3.2.7.2.1.6 1.3.6.1.4.1.21678.313.3.2.7.2.1.7 1.3.6.1.4.1.21678.313.3.2.7.2.1.8 1.3.6.1.4.1.21678.313.3.2.7.2.1.9 1.3.6.1.4.1.21678.
ISO 9001:2000 Cert. N°4500/1 OID 1.3.6.1.4.1.21678.315.1 1.3.6.1.4.1.21678.315.1.1 t2Measure t2mStatistics 1.3.6.1.4.1.21678.315.1.1.1 meas1RxLevel R 1.3.6.1.4.1.21678.315.1.1.2 meas2RxLevel R 1.3.6.1.4.1.21678.315.1.1.3 1.3.6.1.4.1.21678.315.1.1.4 1.3.6.1.4.1.21678.315.1.1.5 1.3.6.1.4.1.21678.315.1.1.6 1.3.6.1.4.1.21678.315.1.1.7 1.3.6.1.4.1.21678.315.1.1.8 1.3.6.1.4.1.21678.315.1.1.9 1.3.6.1.4.1.21678.315.1.1.10 1.3.6.1.4.1.21678.315.1.1.11 1.3.6.1.4.1.21678.315.1.1.12 1.3.6.1.4.1.21678.315.1.1.
ISO 9001:2000 Cert. N°4500/1 OID 1.3.6.1.4.1.21678.315.1.2.17 1.3.6.1.4.1.21678.315.1.2.18 1.3.6.1.4.1.21678.315.1.2.19 1.3.6.1.4.1.21678.315.1.2.20 1.3.6.1.4.1.21678.315.1.2.21 1.3.6.1.4.1.21678.315.1.2.22 1.3.6.1.4.1.21678.315.1.2.23 1.3.6.1.4.1.21678.315.1.2.24 1.3.6.1.4.1.21678.315.1.3 1.3.6.1.4.1.21678.315.1.3.1 1.3.6.1.4.1.21678.315.1.3.2 1.3.6.1.4.1.21678.315.1.3.3 1.3.6.1.4.1.21678.315.1.3.4 1.3.6.1.4.1.21678.315.1.3.5 1.3.6.1.4.1.21678.315.1.3.5.1 1.3.6.1.4.1.21678.315.1.3.5.2 1.3.6.1.4.1.21678.
ISO 9001:2000 Cert. N°4500/1 OID 1.3.6.1.4.1.21678.315.1.3.7.2.1.6 1.3.6.1.4.1.21678.315.1.3.7.2.1.7 1.3.6.1.4.1.21678.315.1.3.7.2.1.8 1.3.6.1.4.1.21678.315.1.3.7.2.1.9 1.3.6.1.4.1.21678.315.1.3.7.2.1.10 1.3.6.1.4.1.21678.315.1.3.7.2.1.11 1.3.6.1.4.1.21678.315.1.3.7.2.1.12 1.3.6.1.4.1.21678.315.1.3.7.2.1.13 1.3.6.1.4.1.21678.315.1.3.7.2.1.14 1.3.6.1.4.1.21678.315.1.3.7.2.1.15 1.3.6.1.4.1.21678.315.1.3.7.2.1.16 1.3.6.1.4.1.21678.315.1.3.7.2.1.17 1.3.6.1.4.1.21678.315.1.3.7.2.1.18 1.3.6.1.4.1.21678.315.1.3.
ISO 9001:2000 Cert. N°4500/1 OID 1.3.6.1.4.1.21678.315.2.2.4 1.3.6.1.4.1.21678.315.2.2.5 1.3.6.1.4.1.21678.315.2.2.6 1.3.6.1.4.1.21678.315.2.2.7 1.3.6.1.4.1.21678.315.3 1.3.6.1.4.1.21678.315.3.1 Name tmdpLpCodeRate tmdpFft tmdpGuardInterval tmdpCelllId isdbtMeasure imStatistics 1.3.6.1.4.1.21678.315.3.1.1 imsMonTxLevel R 1.3.6.1.4.1.21678.315.3.1.2 1.3.6.1.4.1.21678.315.3.1.3 1.3.6.1.4.1.21678.315.3.1.4 1.3.6.1.4.1.21678.315.3.1.5 1.3.6.1.4.1.21678.315.3.1.6 1.3.6.1.4.1.21678.315.3.1.7 1.3.6.1.4.1.
ISO 9001:2000 Cert. N°4500/1 OID 1.3.6.1.4.1.21678.315.4.1.5 1.3.6.1.4.1.21678.315.4.1.6 1.3.6.1.4.1.21678.315.4.1.7 1.3.6.1.4.1.21678.315.4.1.8 1.3.6.1.4.1.21678.315.4.1.9 1.3.6.1.4.1.21678.315.4.1.10 1.3.6.1.4.1.21678.315.4.1.11 1.3.6.1.4.1.21678.317 1.3.6.1.4.1.21678.317.1 1.3.6.1.4.1.21678.317.1.1 1.3.6.1.4.1.21678.317.1.2 1.3.6.1.4.1.21678.317.1.3 1.3.6.1.4.1.21678.317.1.3.1 1.3.6.1.4.1.21678.317.1.3.2 1.3.6.1.4.1.21678.317.1.3.2.1 1.3.6.1.4.1.21678.317.1.3.2.1.1 1.3.6.1.4.1.21678.317.1.3.2.1.2 1.3.6.
ISO 9001:2000 Cert. N°4500/1 OID 1.3.6.1.4.1.21678.317.3.3 1.3.6.1.4.1.21678.317.3.4 1.3.6.1.4.1.21678.317.3.4.1 1.3.6.1.4.1.21678.317.3.4.1.1 1.3.6.1.4.1.21678.317.3.4.1.2 1.3.6.1.4.1.21678.317.3.4.1.3 1.3.6.1.4.1.21678.317.3.4.1.4 1.3.6.1.4.1.21678.317.3.4.1.5 1.3.6.1.4.1.21678.317.4 1.3.6.1.4.1.21678.317.4.1 1.3.6.1.4.1.21678.317.4.2 1.3.6.1.4.1.21678.317.4.3 1.3.6.1.4.1.21678.317.4.3.1 1.3.6.1.4.1.21678.317.4.3.2 1.3.6.1.4.1.21678.317.4.3.2.1 1.3.6.1.4.1.21678.317.4.3.2.1.1 1.3.6.1.4.1.21678.317.4.3.2.
ISO 9001:2000 Cert. N°4500/1 OID Name 1.3.6.1.4.1.21678.317.4.4.1.10 alR1Enable RW 1.3.6.1.4.1.21678.317.4.4.1.11 alR2Enable RW 1.3.6.1.4.1.21678.317.4.4.1.12 alR3Enable RW 1.3.6.1.4.1.21678.317.4.4.1.13 alFrontPanelEnable RW 1.3.6.1.4.1.21678.317.4.4.1.14 alJavaEnable RW 1.3.6.1.4.1.21678.317.4.4.1.15 1.3.6.1.4.1.21678.317.4.4.1.16 1.3.6.1.4.1.21678.317.4.4.1.17 1.3.6.1.4.1.21678.317.5 1.3.6.1.4.1.21678.317.5.1 1.3.6.1.4.1.21678.317.5.2 1.3.6.1.4.1.21678.317.5.2.1 1.3.6.1.4.1.21678.317.5.
ISO 9001:2000 Cert. N°4500/1 OID 1.3.6.1.4.1.21678.317.6.2.2.1.1 1.3.6.1.4.1.21678.317.6.2.2.1.2 1.3.6.1.4.1.21678.317.6.2.2.1.3 1.3.6.1.4.1.21678.321 1.3.6.1.4.1.21678.321.1 1.3.6.1.4.1.21678.321.1.1 1.3.6.1.4.1.21678.321.1.2 1.3.6.1.4.1.21678.321.1.2.1 1.3.6.1.4.1.21678.321.1.2.1.1 1.3.6.1.4.1.21678.321.1.2.1.2 1.3.6.1.4.1.21678.321.1.2.1.3 1.3.6.1.4.1.21678.321.1.2.1.4 1.3.6.1.4.1.21678.321.1.2.1.
ISO 9001:2000 Cert. N°4500/1 OID 1.3.6.1.4.1.21678.325.2.2.2 1.3.6.1.4.1.21678.325.2.2.3 1.3.6.1.4.1.21678.325.2.2.4 1.3.6.1.4.1.21678.325.2.2.5 1.3.6.1.4.1.21678.325.2.3 1.3.6.1.4.1.21678.325.2.3.1 1.3.6.1.4.1.21678.325.2.3.1.1 1.3.6.1.4.1.21678.325.2.3.1.2 1.3.6.1.4.1.21678.325.2.3.2 1.3.6.1.4.1.21678.325.2.3.2.1 1.3.6.1.4.1.21678.325.2.3.2.2 1.3.6.1.4.1.21678.325.2.3.2.3 1.3.6.1.4.1.21678.325.2.3.2.4 1.3.6.1.4.1.21678.325.2.3.2.5 1.3.6.1.4.1.21678.325.2.3.3 1.3.6.1.4.1.21678.325.2.3.4 1.3.6.1.4.1.21678.
ISO 9001:2000 Cert. N°4500/1 OID 1.3.6.1.4.1.21678.325.3.3.1 1.3.6.1.4.1.21678.325.3.3.2 1.3.6.1.4.1.21678.325.3.3.3 1.3.6.1.4.1.21678.325.3.3.4 1.3.6.1.4.1.21678.325.3.3.5 1.3.6.1.4.1.21678.325.4 1.3.6.1.4.1.21678.325.4.1 1.3.6.1.4.1.21678.325.4.1.1 1.3.6.1.4.1.21678.325.4.1.2 1.3.6.1.4.1.21678.325.4.1.3 1.3.6.1.4.1.21678.325.4.1.4 1.3.6.1.4.1.21678.325.4.1.5 1.3.6.1.4.1.21678.325.4.1.6 1.3.6.1.4.1.21678.325.4.1.7 1.3.6.1.4.1.21678.325.4.2 1.3.6.1.4.1.21678.325.4.2.1 1.3.6.1.4.1.21678.325.4.2.2 1.3.6.1.4.
ISO 9001:2000 Cert. N°4500/1 7.3 Events Monitoring In MIB ssbtCommon the events node allows the monitoring of events. evNumber object specifies the total number of events stored in memory. evOverwritten object notifies if the events list exceeded the memory limit. If this object returns “1”, obsolete events have begun to be overwritten. evPageSel object selects which page has to be monitored through the events table. Each page is composed by 16 events.
ISO 9001:2000 Cert. N°4500/1 7.4 Configuring alarm masks and alarm thresholds In ssbtCommon MIB the alarms node allows the monitoring of alarms status, the setting of alarm masks and thresholds. 7.4.1 Alarms Table The alTable table is used to monitor alarms status and to set alarm masks. alNumber object specifies the total number of entries in the alarms table. alSeverityStatus specifies the maximum severity of currently raised alarms.
ISO 9001:2000 Cert. N°4500/1 alTrapManager2 object allows to enable trap messages, associated to the entry, to be sent to the manager with IP address 2 alTrapManager3 object allows to enable trap messages, associated to the entry, to be sent to the manager with IP address 3 alR0Enable, alR1Enable, alR2Enable, alR3Enable objects enable relay 0, 1, 2, 3 respectively, to be switched on/off depending on the status of this entry.
ISO 9001:2000 Cert.
ISO 9001:2000 Cert. N°4500/1 7.4.2 Thresholds Table The alThresholds subtree is used to set alarms thresholds. altNumber object specifies the total number of entries in the alarm thresholds table. Each entry in the table is defined as follows: AltEntry ::= SEQUENCE { altIndex INTEGER, altDescr DisplayString, altAlarmCode INTEGER, altMeasUnit MeasureType, altSetting INTEGER } altIndex is the index of the specific entry.
ISO 9001:2000 Cert. N°4500/1 Table 32. altDescr Alarm Thresholds Description Threshold Description Alarm Code Temp. High -3dB Temperature warning threshold expressed in °C. 1 Temp. High Warning Temperature alarm threshold expressed in °C. 2 FWD Pwr Low Warning Forward power warning threshold expressed in dB. 17 FWD Pwr Low Forward power alarm threshold expressed in dB. 18 FE Squelch [DVB-T2] FE Squelch alarm threshold expressed in dB.
ISO 9001:2000 Cert. N°4500/1 altDescr Threshold Description Alarm Code Meas S.Quality Low [DVB-T] MEAS Signal Quality Low alarm threshold. 818 FE SNR Low [ATSC] FE SNR Low alarm threshold (expressed in dB*1e3). 1062 Meas SNR Low [ATSC] MEAS SNR Low alarm threshold (expressed in dB*1e3). 1060 Version 1.
ISO 9001:2000 Cert. N°4500/1 7.5 Traps While a management station can poll, at fixed time interval, all the agents it knows for some key information, each agent is responsible for notifying the management station of any alarm condition. These events are communicated in SNMP messages known as traps. The following parameters shall be set in order to correctly configure traps: SNMP Agent Port: 162. SNMP Agent Transport protocol: IP/UDP. 7.5.1 SNMPv1 ARK6 devices transmit alarm-specific traps.
ISO 9001:2000 Cert. N°4500/1 VARIABLES clause defines the ordered sequence of MIB objects, belonging to the specific entry of the alTable, which are contained within every instance of the trap type. Each variable is placed, in order, inside the variablebindings field of the SNMP Trap Message as shown in the following figure (refer to Alarms Table paragraph for further information about alIndex, alStatus, alCode, alDesc, alSeverity objects). Figure 58. Version 1.
ISO 9001:2000 Cert. N°4500/1 7.5.2 SNMPv2 ARK6 devices transmit alarm-specific traps. For every Trap Manager there is a different SNMv2 trap definition: traps OBJECT IDENTIFIER ::= { snmp 3 } alarmTraps1 NOTIFICATION-TYPE OBJECTS {alIndex, alStatus, alCode, alDescr, alSeverity} STATUS current DESCRIPTION "Traps definition for Trap Manager 1. An alarmTrap1 trap signifies that the sending protocol entity recognizes that some state transitions occurred in the alarms table.
ISO 9001:2000 Cert. N°4500/1 VARIABLES clause defines the ordered sequence of MIB objects, belonging to the specific entry of the alTable, which are contained within every instance of the trap type. Each variable is placed, in order, inside the variablebindings field of the SNMP Trap Message as shown in the following figure (refer to Alarms Table paragraph for further information about alIndex, alStatus, alCode, alDesc, alSeverity objects). Figure 59. Version 1.
ISO 9001:2000 Cert. N°4500/1 7.5.3 Configuring traps Use Java (refer to Network and Alarms paragraphs for further information) or SNMP user interfaces to configure traps.
ISO 9001:2000 Cert. N°4500/1 Appendix A. A.1 Automatic input source selection methods Input Autoswitch The SDT ARK62 series supports an automatic switching control mechanism between incoming signal sources. The ARK6 is capable of switching between inputs on the basis of primary feed quality, depending on how it is presented to the transmitter (RF, ASI – Ethernet, SDI and CVBS feeds). The feed switching algorithm is irrespective of payload and bitrate of both primary and reserve feeds.
ISO 9001:2000 Cert. N°4500/1 Input switching rules can be selected in the Alarms page through the SWITCH alarm mask and depend on the transmission standard.
ISO 9001:2000 Cert. N°4500/1 Feed selection and switching criteria are available via both transmitter SNMP and Java GUI interfaces. A Finite State Machine has been used to give a description of the behaviour of the system. The FSM of the Input Autoswitch algorithm consists of: Four states: 1. Priority Input Locked 2. 3. 4. Priority Input Not Locked Condition 1: the primary feed does not meet the necessary quality requirements as well as reserve feeds, if any.
ISO 9001:2000 Cert. N°4500/1 A.2 Seamless input switching SDT ARK6 series supports a seamless input switching algorithm that increases the reliability of the system in a SFN environment. The developed algorithm is capable of changing input signal source on the basis of MIP packets within the incoming Transport Stream. The algorithm provides a reserve feed to the apparatus in a SFN environment in the event that the primary input signal source does not meet anymore the SFN constrains.
ISO 9001:2000 Cert. N°4500/1 Appendix B. Java Virtual Machine The Java interface requires a host computer connected via Ethernet to the board with the proper Java Machine version installed. Ethernet connection B.1 The host computer has to be connected via Ethernet to the board. Direct or crossed UTP category 6 cable is recommended. NOTE: for best performances, a fast connection (i.e. gigabit Ethernet) is required.
ISO 9001:2000 Cert. N°4500/1 Appendix C. Application Note Screenshots of this application note are used as an example and the shown file names are not related to ARK6T2 device. C.1 How to update 1. Launch the Java installer. Figure 60. 2. Insert the IRRM2 BTS Remux IP address into the numeric field. Figure 61. Version 1.
ISO 9001:2000 Cert. N°4500/1 3. Click the Search button. Figure 62. 4. Select the device version you want to load. Figure 63. Version 1.
ISO 9001:2000 Cert. N°4500/1 5. Click on the “Load” button. Figure 64. 6. If you want to update only some software versions, click on the check boxes corresponding to the software version you want to load, otherwise click on the check box corresponding to the Load All option. Click on the “Enter” button to start the loading. Figure 65. Version 1.
ISO 9001:2000 Cert. N°4500/1 7. Once started the loading, the “Stop” button lights up. Click on this button to interrupt the programming. Figure 66. 8. When the loading is complete, the pop-up window “Operation Successfully Completed” appears. Click on the “OK” button. Figure 67. Version 1.
ISO 9001:2000 Cert. N°4500/1 9. To save a copy of the file system click on “Backup” button. A pop-up window “Salva” appears. Specify the saving path, then click on “Salva” button. Figure 68. Version 1.
ISO 9001:2000 Cert. N°4500/1 Appendix D. Document versions Table 33. Version Author Revised by Document Versions Date Note 1.0 Di Biase November 8th, 2011 First version with all the operative modes. 1.1 Di Biase November 23rd, 2011 Updated paragraphs 4.2 and 4.4. Version 1.
ISO 9001:2000 Cert. N°4500/1 List of Tables Table 1. Hardware options .................................................................................................................... 8 Table 2. RS232 DE-9 pinout ................................................................................................................. 23 Table 3. TLC pinout.............................................................................................................................. 23 Table 4. TLS pinout ..
ISO 9001:2000 Cert. N°4500/1 List of Figures Figure 1. DE-9 Male connector ............................................................................................................. 23 Figure 2. TLC connector ........................................................................................................................ 23 Figure 3. TLS connector ........................................................................................................................ 24 Figure 4.
ISO 9001:2000 Cert. N°4500/1 Figure 35. Adaptive Non Linear Precorrection ....................................................................................... 74 Figure 36. Output window...................................................................................................................... 76 Figure 37. Reflex Pwr Management ....................................................................................................... 85 Figure 38. Network window ..................................