Description-Event
Event Description
Save drlin err: xx
An error occurs during saving linear precorrection coefficients.
xx: error code:
0x80: File system busy;
0x01: New *.drlin file opening error;
0x02: number of coefficients information writing error;
0x03: linear coefficients writing error;
0x07: File date writing error;
0x08: Old *.drlin file deleting error
0x09: New file naming error (deleting of “*”);
0x10: file already opened;
0x0A: File date writing error it can’t be found into the FS.
New T2MI PID N
New T2-MI PID found by the Automatic T2-MI PID Mode mechanism.
IIC Error
IIC bus error
DVB-T2 params err xx
An error occurs during T2 parameters loading.
xx: error code:
0x01: P1 symbol loading error;
0x02: P1 symbol loading error due to a not valid T2-MI input.
Re-start mode
When DVB-T2 params err 01 occurs during T2 parameters loading,
the FPGA firmware is reloaded and this event is generated.
DVB-T2 preset err xx
An error occurs during T2 preset configuration loading.
xx: error code:
0x80: File system busy;
0x01: *.t2cfg file opening error;
0x02: *.t2cfg file header reading error;
0x03: the selected configuration is corrupted;
0x04: preset configuration data too big;
0x05: memory allocation error;
0x06: *.t2cfg file header reading error;
0x09: *.t2cfg file not found;
0x10: the selected configuration is not present.
RFL Power Warning
RFL power goes over the alarm threshold for the first time and the
“Number of attempts” is different from zero.
RFL Power OK
RFL power goes under the alarm threshold.
RFL Power Alarm
RFL power goes over the alarm threshold for N times, where N is the
number of attempts specified in the Output page of the Java GUI.
RFL RF ON ”N
When RFL power goes over the alarm threshold the system switch off
and on the output RF signal for a maximum number of times. N is the
current number of attempt.
T2-MI Autodetect PID OK
The Automatic T2-MI PID detection has been put across
T2MI PID PAT Err
During Automatic T2-MI PID operations, PAT has not been found in
the input Transport Stream.
T2-MI PID Not Valid
During Automatic T2-MI PID operations, no PIDs with stream type
x06 has been found in the PMT.
T2MI PID PMT Err
During Automatic T2-MI PID operations, more than one PID with
stream type x06 has been found in the PMT.
T2-MI PID Not Found
During Automatic T2-MI PID operations, the detected T2-MI PID has
not been found in the input Transport Stream
Freq Ref Forced: GPS
If the Network mode is SFN but the clock reference is set to Internal,
the frequency reference is automatically forced to GPS and this event
is generated.
Freq Ref set to string
Event generated at every new Frequency Reference selection.
string: the clock reference
External
Internal
GPS