User's Manual

ISO 9001:2000 Cert. N°4500/1
Version 1.1 SDT_ARK6_User_Manual_ENG_vATSC Page 129 of 206
Description
Errors code
Byte
CALIB_ERR
*.pwr file error.
0x00: File ok.
0x01: Current AGC mode file not found.
0x02: Current AGC mode file open error.
0x03…0x12: Invalid current AGC mode file (syntax error).
0x20: Other AGC mode file not found
0x21: Other AGC mode file open error.
0x22…0x26: Invalid other AGC mode file (syntax error).
Please note that the AGC mode may be analog or digital.
Actual AGC mode is displayed in Java output window.
PREC_ERR
0x00: File ok.
10°
LINEAR_ERR
0x00: File ok.
0x01: File not found.
0x02: File open error.
0x03…0x06: Invalid file (syntax errors).
11°
DOWNCV_ERR
Downconverter PLL not
locked error.
0x00: PLL locked.
0x01: PLL not locked
0x10: PLL disabled.
12°
UPCV_ERR
Upconverter error.
0x00: Upconverter ready.
13°
CH_FILT_ERR
*.chf7 or *.chf8 file error.
0x00: File ok.
0x01: File not found.
0x02: File open error.
0x03…0x06: Invalid file (syntax errors).
Please note that checked file is the one which refers to the
current signal bandwidth: *.chf7 refers to VHF bandwidth, *.chf8
refers to UHF bandwidth.
14°