5.5.1 Tuner window: RF power level monitor
Figure 12. Tuner window: RF power level monitor
Table 6. Tuner window: RF power level monitor
Box
Parameter / Control
Description
Admitted Ranges / Values
General
Rx Level [dBm] /
Progress Bar
Input RF power level monitor expressed in dBm.
Min: -84
Max: -21
Low Power
High Power
General
Low Power Rx Signal
This alarm is raised when Max ADC Value is beneath the Low AGC
Threshold and, consequently, both DAT 1 and DAT 2 are at their
minimum values.
Red: Alarm On
Grey: Alarm Off
General
High Power Rx Signal
This alarm is raised when Max ADC Value is beyond the High AGC
Threshold and, consequently, both DAT 1 and DAT 2 are at their
maximum values.
Red: Alarm On
Grey: Alarm Off
General
Channel
This indicator shows the input RF channel.
VHF:
Min: E2
Max: E12
UHF:
Min: 21
Max: 69
General
Offset [Hz]
This indicator shows the input frequency offset.
Min: - 200 kHz
Max: + 200 kHz
General
Bandwidth [MHz]
Input channel bandwidth.
It depends on the FE Type.