User's Manual
ISO 9001:2000 Cert. N°4500/1
Version 1.1 SDT_ARK6_User_Manual_ENG_vATSC Page 46 of 206
Table 9. ATSC Processing: ATSC Settings
Box
Parameter / Control
Description
Admitted Ranges / Values
Input
Input Selector
Input selector.
It is not allowed to change input until the Input Autoswitch is
enabled. In order to change the primary input, disable the Input
Autoswitch functionality, select a different input through the input
selector and then enable the Input Autoswitch functionality.
ASI 1
ASI 2
ASI 3
ASI 4
Tuner
GbE 2 ch1
GbE 2 ch2
Input
Input Alarm Delay [s]
Time to wait for No Input alarm rising expressed in seconds (refer to
Alarms paragraph).
Note: It is highly recommended to set an Input Alarm Delay value
different from zero so as to allow the input signal locking.
Min: 1 s
Max: 25.5 s
Input Autoswitch
Auto Input Enable
Enables the use of Input Autoswitch finite-state machine.
Refer to Appendix A. for further information.
Enabled
Disabled
Input Autoswitch
Actual Input
Shows the currently used input.
ASI 1
ASI 2
ASI 3
ASI 4
Tuner
GbE 2 ch1
GbE 2 ch2