User's Manual
ISO 9001:2000 Cert. N°4500/1
Version 1.1 SDT_ARK6_User_Manual_ENG_vATSC Page 47 of 206
Box
Parameter / Control
Description
Admitted Ranges / Values
Input Autoswitch
Primary to Secondary
Switch Counter
Primary to secondary input switch countdown expressed in
seconds.
Min: 0 s
Max: *.def file dependant
Default: 25 s
Input Autoswitch
Secondary to
Secondary Switch
Counter
Secondary to secondary input switch countdown expressed in
seconds.
Min: 0 s
Max: *.def file dependant
Default: 25 s
Input Autoswitch
Secondary to Primary
Switch Counter
Secondary to primary input switch countdown expressed in
seconds.
Min: 0 s
Max: *.def file dependant
Default: 300 s
Input Autoswitch
State
Current state of the finite-state machine
Priority Input Locked
Priority Input Not Locked
Searching First Input Locked
Check Priority Input
Tuner
Channel
Input RF channel selector.
Min: 14
Max: 77
Tuner
Offset [Hz]
The receiver frequency will accept offset frequencies in the range
+/- 200 kHz (1 Hz steps).
Min: - 200 kHz
Max: + 200 kHz
FE Alarm
Thresholds
SNR Thr [dB]
FE Signal to Noise alarm threshold.
Min: 10 dB
Max: 50 dB