User's Manual
ISO 9001:2000 Cert. N°4500/1
Version 1.1 SDT_ARK6_User_Manual_ENG_vATSC Page 57 of 206
Box
Parameter / Control
Description
Admitted Ranges / Values
Output
Power [w]
Output power setting.
This control sets the output power in W. Changing this control will
also change the value of power control expressed in dBm.
Min and Max values depends on the
power class of the device. e.g. for a
SDTX-500 device:
0.63 W up to 63 W
Input Autoswitch
Auto Input Enable
Enables the use of Input Autoswitch finite-state machine.
Refer to Appendix A. for further information.
Enabled
Disabled
Input Autoswitch
Actual Input
Shows the currently used input.
SDI 1
SDI 2
SDI 3
SDI 4
CVBS 1
CVBS 2
Input Autoswitch
Primary to Secondary
Switch Counter
Primary to secondary input switch countdown expressed in
seconds.
Min: 0 s
Max: *.def file dependant
Default: 25 s
Input Autoswitch
Secondary to
Secondary Switch
Counter
Secondary to secondary input switch countdown expressed in
seconds.
Min: 0 s
Max: *.def file dependant
Default: 25 s
Input Autoswitch
Secondary to Primary
Switch Counter
Secondary to primary input switch countdown expressed in
seconds.
Min: 0 s
Max: *.def file dependant
Default: 300 s