User's Manual
ISO 9001:2000 Cert. N°4500/1
Version 1.1 SDT_ARK6_User_Manual_ENG_vATSC Page 61 of 206
Table 13. ITU Modulation: Modulator manager
Box
Parameter / Control
Description
Admitted Ranges / Values
Video
White Level [%]
Video white level setting. The level value is in percentage upon the
synch level. The synch level is taken as 100% reference.
MIN: 10
MAX: 22
Step: 0,05
Video
Synch. Amplitude
[%]
Video synch amplitude setting. The level value is in percentage
upon the synch level. The synch level is taken as 100% reference.
MIN: 22
MAX: 27,5
Step: 0,05
Video
Pedes Level [%]
Video pedes level setting. The level value is in percentage upon the
synch level. The synch level is taken as 100% reference.
MIN: 0
MAX: 7
Step: 0,05
Audio
Deviation
Audio deviation.
This parameter is used to change the frequency deviation of the
audio modulation in order to adjust the audio volume.
Relative values
0 up to 255
Default value 100
Audio
Carrier Level 1 [dB]
Audio 1 carrier level setting.
This parameter is the amplitude difference, expressed in dB values,
between the video carrier and the audio 1 carrier.
MIN: -22
MAX: -7
Step: 1