User's Manual

ISO 9001:2000 Cert. N°4500/1
Version 1.1 SDT_ARK6_User_Manual_ENG_vATSC Page 67 of 206
In the module grid, the red curve is used to monitor the current module curve calculating and saving.
The last saved coefficients are locally downloaded from the FPGA runtime memory registers in order to
redraw the curve.
Remember to click on the Save as button the first time you change the factory default curves in order to
do not overwrite them.
The following buttons allow the management of linear pre-correction files and the management of the
connection to port 5000:
Save: used to save in the device memory the current curves setting. The previously saved file
will be overwritten except in the event that no files have been saved before; in this case a
dedicated window appears in order to let the user name the new file.
Save as: used to save in the device memory the current curves setting. The previously saved file
will be overwritten with a new name. In the event that no files have been saved before, a new
file will be created.
Read file: used to reload the last saved file.
Export: used to download pre-correction files on the user PC. A browser window allows the
selection of the saving path.
Release: releases the connection in order to allow others remote machines to connect to port
5000 (refer to Connection to port 5000 paragraph).