User's Manual
ISO 9001:2000 Cert. N°4500/1
Version 1.1 SDT_ARK6_User_Manual_ENG_vATSC Page 72 of 206
5.9.1.2 Adaptive Linear Precorrection: Management panel
Table 15. Adaptive Linear Precorrection: Management panel
Box
Parameter / Control
Description
Admitted Ranges / Values
General
Load
Loads filter coefficients from the respective FPGA registers.
General
Clear
Loads flat curve coefficients.
General
Timeout [s]
Once enabled, the adaptive linear compensation has a timeout.
When the timeout is expired, the precorrection is stopped. In order
to continue updating coefficients, click on ON/OFF button.
Fixed to 60 seconds
General
Save
Saves the current adaptive filter coefficients.
General
ON/OFF
Enables the adaptive linear compensation.
ON(Green):Enabled
OFF(Red): Disabled
General
Status
Shows the type of adaptive compensation currently used, if any.
None
Linear
Non Linear
General
Low Power Rx Signal
Indicates that the signal that re-enters the system has a low power.
When this flag is on, the automatic update of the filter coefficients is
stopped.
Red: Alarm On
Grey: Alarm Off
General
High Power Rx Signal
Indicates that the signal that re-enters the system has a high power.
When this flag is on, the automatic update of the filter coefficients is
stopped.
Red: Alarm On
Grey: Alarm Off