User's Manual
ISO 9001:2000 Cert. N°4500/1
Version 1.1 SDT_ARK6_User_Manual_ENG_vATSC Page 75 of 206
5.9.2.1 Adaptive Non Linear Precorrection: Management panel
Table 16. Adaptive Non Linear Precorrection: Management panel
Box
Parameter / Control
Description
Admitted Ranges / Values
General
Clear
Resets the filter coefficients to zero.
General
ON/OFF
Enables the adaptive non linear compensation.
ON(Green):Enabled
OFF(Red): Disabled
General
Status
Shows the type of adaptive compensation currently used, if any.
None
Linear
Non Linear
General
Low Power Rx Signal
Indicates that the signal that re-enters the system has a low power.
When this flag is on, the automatic update of the filter coefficients is
stopped.
Red: Alarm On
Grey: Alarm Off
General
High Power Rx Signal
Indicates that the signal that re-enters the system has a high power.
When this flag is on, the automatic update of the filter coefficients is
stopped.
Red: Alarm On
Grey: Alarm Off