User's Manual
ISO 9001:2000 Cert. N°4500/1
Version 1.1 SDT_ARK6_User_Manual_ENG_vATSC Page 78 of 206
Box
Parameter / Control
Description
Admitted Ranges / Values
Status
PS 26V [V]
First PSU voltage indicator, expressed in Volt, for SDTx20,
SDTx50, SDTx201 and SDTx501 devices.
Min: 24V
Max: 28V
Status
PS Current 26V [A]
First PSU current indicator, expressed in Ampere, for SDTx20,
SDTx50, SDTx201 and SDTx501 devices.
Max: 8A
Status
PS1 50V [V]
Second PSU voltage indicator, expressed in Volt, for SDTx201 and
SDT501 devices.
Min: 45V
Max: 55V
Status
PS1 Current 50V [A]
Second PSU current indicator, expressed in Ampere, for SDTx201
and SDT501 devices.
Max: 18A
Status
PS2 50V [V]
Third PSU voltage indicator, expressed in Volt, for SDTx501
devices.
Min: 45V
Max: 55V
Status
PS2 Current 50V [A]
Third PSU current indicator, expressed in Ampere, for SDTx501
devices.
Max: 18A
Status
Ampli status
Current amplifier status indicator:
1. ON: the amplifier has been manually set to on and no alarms
or settings switched it off
2. PS Alarm OFF: when an alarm of over current, over voltage or
over power occurs on the second or third Power Supply, the
Amplifier is restarted four times, if the alarm is still on, the
Amplifier is automatically switched off. Single Power Supply
models do not support this status
3. Restart: the amplifier has been automatically restarted due to
an alarm for over current, over voltage or forward power
exceeding the upper limit on the second Power Supply. Single
Power Supply models do not support this status
4. Stand-by OFF: the equipment has been put on Standby mode
and the amplifier has been automatically muted
5. Init: at every amplifier initialization the amp is automatically
switched off.
ON
PS Alarm OFF
Restarting
Stand-by OFF
Init
Alarm OFF
RF OFF
Opto OFF
Change mode
Missing file OFF